8 PRODIGIT
2-9 Connection to the load Input Terminal on the Rear Panel
Connection procedure of the load input terminal on the rear panel
2.9.1. Turn off POWER switch.
2.9.2. Check that the output of the equipment under test is off.
2.9.3. Check the polarity of the connection and connect the load wire to the output
Terminal of the equipment under test.
2-10 RS232 interface option
Fig 2-3 shows the RS232 interface (Female) on the rear panel connects 4016 Series
Digital Power Analyzer to RS232 port of computer in one by one configuration .The
RS232 BAUD-RATE can be set in the front panel
Fig 2-3 4016 Series RS232 interface
2-11 GPIB interface option
2.11.1 The maximum number of devices including the controller is no more than 15.
2.11.2 The maximum length of all cable is no more than 2 meters times the number
Of devices connected together, up to 20 meters maximum.
Fig 2-4 4016 Series GPIB interface
2-12 USB interface option
Fig 2-5 shows the USB interface in the rear panel of 4016 Series Digital Power
Analyzer . Please Refer Appendix B.
Fig 2-5 4016 Series USB interface