1
Read Me First
for the ProCurve Series 8100fl Switches – Software Version CY.01.02.0050
Contents
ProCurve Series 8100fl Operation and Installation Notes
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 1
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 1
About Your ProCurve Series 8100fl Switches Manual Set
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3
Open Source Software Acknowledgement
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3
ProCurve Series 8100fl Operation and Installation Notes
■
System Clock.
To ensure correct operation of your switch, you must update the system clock and
reload prior to configuration. This is required only for the initial installation and configuration of your
system. See
“Setting the System Clock” on page 1
■
Installation Caution.
To avoid personal injury or product damage, read the safety warnings and
installation precautions listed in the
Installation and Getting Started Guide
included with your switch.
Never attempt to mount a ProCurve Switch 8100fl unaided.
■
Version B mini-GBICs only.
The Series 8100fl Switches do not support “A” version ProCurve
mini-GBICs. Use only ProCurve JxxxxB version mini-GBICs with your switch. See
for details.
■
Scratchpad versus Running Config.
Configuration commands you enter during a CLI session are
stored in a temporary location called a “scratchpad”, and do not get entered into the running
configuration until you perform a
save active
command. For details on saving changes to the
startup-config and running-config, refer to the
Management and Configuration Guide
on the
Documentation CD-ROM
included with your switch.
■
Console Serial Port is only 9600 baud.
There is no auto-baud detect on the switch. To connect a
console to the switch, configure your VT-100 terminal to operate with the following settings:
9600 baud rate/8 data bits/1 stop bit/no parity/no flow control.
■
Out of band Management Port.
The 10/100Base-T Ethernet port on the management module is for
management only. It cannot be used for switching network traffic. The port is not auto-MDIX.
Setting the System Clock
To set the system date and time, use the
clock set
command from the command line interface (CLI). For more
information refer to the chapter on “Getting Started with Switch Configuration” in the
Installation and Getting
Started Guide
included with your switch. You can verify the clock settings using the
show clock
command.
For example:
Switch 8100fl#clock set 18:45:29 30 September 2005
Switch 8100fl#show clock
*18:45:29 UTC Fri September 30 2005