61195888L1-13D, May 2006
www.procurve.com
Copyright 2006 Hewlett-Packard Development Company, LP
Quick Start Guide
5990-8896
ProCurve Secure Router dl 2xE1 Module
J8456A
S
PECIFICATIONS
Operating Modes
E1/FE1 Frame Relay, E1/FE1 PPP, E1/FE1 HDLC,
E1/FE1 Multilink Frame Relay, E1/FE1 Multilink PPP
E1/FE1
Interfaces
Supported Standards: ITU-T G.703, ITU-T G.704 (CRC-4),
ITU-T G.797, ITU-T G.823
Line Rate: 2.048 Mbps ±50 PPM
Line Code: AMI or HDB3
Framing: FAS with optional CRC-4
Receiver Sensitivity: -30 dB
FE1 Line Rate: Channelized timeslot (in multiples of
56/64 kbps)
Connector: RJ-48C
Clock Source
Network, internal, and through
Diagnostics
Test Pattern Generation and Detection: QRSS, 2
15
- 1,
all ones, all zeros
Network loopbacks
Alarm generation and detection
Network performance data (15 minutes and 24 hours)
Standards
FCC Part 15 Class A, EN 55022 Class A, EN 55024,
EN 61000-3-2, EN 61000-3-3
ACIF S016, ETSI TBR 12/TBR 13
EN 60950, IEC 60950, AS/NZS 60950
Physical
Dimensions: 6.99 cm (2.75 in) W x 10.80 cm (4.25 in) D
Operating Temperature: 0°C to 50°C (32°F to 122°F)
Relative Humidity: Up to 95 percent, noncondensing
at 30°C (86°F)
Non-Operating Temperature: -20°C to 70°C (-4°F to 158°F)
Non-Operating Relative Humidity: Up to 95 percent,
noncondensing at 30°C (86°F)
Altitude: Up to 3.05 km (10,000 ft)
I
NSTALLATION
I
NSTRUCTIONS
Warning
For ProCurve Secure Router modules with outside
plant connections,
e
nsure that all cables are removed
from the module before installing or removing it from
the router chassis.
1.
Remove power from the unit.
2.
Slide the ProCurve Secure Router dl 2xE1 Module into the option slot
until the module is firmly seated against the chassis.
3.
Secure the screws at both edges of the module.
4.
Connect the cables to the associated device(s).
5.
Complete the installation of the base unit.
6.
Restore power to the unit.
Note
For safety information for the routers and all modules,
please refer to the safety and ESD precautions in the
ProCurve Secure Router Installation Guide
included
in your router shipment.
E1 N
ETWORK
(RJ-48C) C
ONNECTION
P
INOUT
Pin
Name
Description
1
R1
Receive data from the network
2
T1
Receive data from the network
3
—
Unused
4
R
Transmit data toward the network
5
T
Transmit data toward the network
6-8
—
Unused
Note
An optional backup module is required for backup
applications.
For a description of the backup connection pinouts,
refer to the Quick Start Guide included with your