ProCurve J8456A Скачать руководство пользователя страница 1

61195888L1-13D, May 2006

www.procurve.com

Copyright 2006 Hewlett-Packard Development Company, LP

Quick Start Guide

5990-8896

ProCurve Secure Router dl 2xE1 Module

J8456A

S

PECIFICATIONS

Operating Modes

E1/FE1 Frame Relay, E1/FE1 PPP, E1/FE1 HDLC,
E1/FE1 Multilink Frame Relay, E1/FE1 Multilink PPP

E1/FE1 
Interfaces

Supported Standards: ITU-T G.703, ITU-T G.704 (CRC-4),
ITU-T G.797, ITU-T G.823
Line Rate: 2.048 Mbps ±50 PPM
Line Code: AMI or HDB3
Framing: FAS with optional CRC-4
Receiver Sensitivity: -30 dB
FE1 Line Rate: Channelized timeslot (in multiples of 
56/64 kbps)
Connector: RJ-48C

Clock Source

Network, internal, and through

Diagnostics

Test Pattern Generation and Detection: QRSS, 2

15 

- 1,

all ones, all zeros
Network loopbacks 
Alarm generation and detection
Network performance data (15 minutes and 24 hours)

Standards

FCC Part 15 Class A, EN 55022 Class A, EN 55024,
EN 61000-3-2, EN 61000-3-3
ACIF S016, ETSI TBR 12/TBR 13
EN 60950, IEC 60950, AS/NZS 60950

Physical

Dimensions: 6.99 cm (2.75 in) W x 10.80 cm (4.25 in) D 
Operating Temperature: 0°C to 50°C (32°F to 122°F)
Relative Humidity: Up to 95 percent, noncondensing
at 30°C (86°F)
Non-Operating Temperature: -20°C to 70°C (-4°F to 158°F)
Non-Operating Relative Humidity: Up to 95 percent, 
noncondensing at 30°C (86°F)
Altitude: Up to 3.05 km (10,000 ft)

I

NSTALLATION

 I

NSTRUCTIONS

Warning

For ProCurve Secure Router modules with outside 
plant connections, 

e

nsure that all cables are removed 

from the module before installing or removing it from 
the router chassis.

1.

Remove power from the unit.

2.

Slide the ProCurve Secure Router dl 2xE1 Module into the option slot 
until the module is firmly seated against the chassis.

3.

Secure the screws at both edges of the module.

4.

Connect the cables to the associated device(s).

5.

Complete the installation of the base unit.

6.

Restore power to the unit.

Note

For safety information for the routers and all modules, 
please refer to the safety and ESD precautions in the 

ProCurve Secure Router Installation Guide

 included 

in your router shipment.

E1 N

ETWORK

 (RJ-48C) C

ONNECTION

 P

INOUT

Pin

Name

Description

1

R1

Receive data from the network

2

T1

Receive data from the network

3

Unused

4

R

Transmit data toward the network

5

T

Transmit data toward the network

6-8

Unused

Note

An optional backup module is required for backup 
applications.
For a description of the backup connection pinouts, 
refer to the Quick Start Guide included with your 
backup module