INSPECTING HEATER
1/2 Glass
Height
1/2 Glass
Height
Yellow
Tipping
Figure 24 - Correct Burner Flame Pattern
Figure 25 - Incorrect Burner Flame
Pattern
Notice: Do not mistake orange flames with yellow tipping. Dirt or other fine particles enter the
heater and burn causing brief patches of orange flame.
BURNER FLAME PATTERN
Figure 24 shows a correct burner flame pat-
tern. Figure 25 shows an incorrect burner
flame pattern. The incorrect burner flame
pattern shows yellow tipping of the flame. It
also shows the flame higher than 1/2 the heat
shield height.
If burner flame pattern is incorrect, as shown
in Figure 25
• turn heater off (see
To Turn Off Gas to Ap-
pliance
, page 17 or 18)
• see
Troubleshooting
pages 20 through 24.
CARE AND MAINTENANCE
WARNING: Turn off heater and let cool before servicing. Only a
qualified service person should service and repair heater.
CAUTION: You must keep control areas, burner, and circulating
air passageways of heater clean. Inspect these areas of heater before
each use. Have heater inspected yearly by a qualified service techni-
cian. Heater may need more frequent cleaning due to excessive lint
from carpeting, bedding material, pet hair, etc.
CAUTION: Never use a wire, needle, or similar object to clean
ODS/pilot. This can damage ODS/pilot unit.
ODS/PILOT AND BURNER
Use a vacuum cleaner, pressurized air, or a small, soft bristled brush to clean.