LOCAL CODES

Install  and  use  heater  with  care.  Follow  all 

local codes. In the absence of local codes, 

use  the  latest  edition  of 

The  National  Fuel 

Gas Code, ANSI Z223.1/NFPA 54

*.

*Available from:

American National Standards Institute, Inc.

25 West 43rd Street

New York, NY  10036

National Fire Protection Association, Inc.

1 Batterymarch Park

Quincy, MA  02269-9101

State of Massachusetts:

 The installation 

must  be  made  by  a  licensed  plumber  or 

gas  fitter  in  the  Commonwealth  of  Mas

-

sachusetts.
Sellers  of  unvented  propane  or  natural 

gas-fired supplemental room heaters shall 

provide to each purchaser a copy of 527 

CMR 30 upon sale of the unit.
In  the  State  of  Massachusetts  the  gas 

cock must be a T-handle type. The State 

of  Massachusetts  requires  that  a  flexible 

appliance connector cannot exceed three 

feet in length.

UNPACKING

1.  Remove heater from carton.
2.  Remove all protective packaging applied 

to heater for shipping

3.  Check heater for any shipping damage. If 

heater is damaged, promptly inform dealer 

where you bought heater.

QUALIFIED INSTALLING AGENCY

Only  a  qualified  agency  should  install  and 

replace gas piping, gas utilization equipment 

or accessories, and repair and equipment ser

-

vicing. The term “qualified agency” means any 

individual, firm, corporation, or company that 

either in person or through a representative 

is engaged in and is responsible for:

  a) Installing, testing, or replacing gas piping 

or

  b) Connecting, installing, testing, repairing, 

or servicing equipment; that is experienced 

in such work; that is familiar with all precau

-

tions required; and that has complied with 

all the requirement of the authority having 

jurisdiction.

PRODUCT FEATURES

SAFETY PILOT

This heater has a pilot with an Oxygen Deple

-

tion Sensing (ODS) safety shutoff system. The 

ODS/pilot shuts off the heater if there is not 

enough fresh air.

PIEZO IGNITION SYSTEM

This heater is equipped with a piezo ignitor. 

this system requires no matches, batteries, or 

other sources to light heater.

THERMOSTATIC CONTROL

(Thermostat Models Only)

These  heaters  have  a  control  valve  with  a 

thermostat sensing bulb. This results in the 

greatest  heater  comfort  and  may  result  in 

lower gas bills.

Содержание ML100HBAHR

Страница 1: ...life Do not store or use gasoline or other flammable va pors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any e...

Страница 2: ...ently located manufactured mobile home where not prohibited by local codes This appliance is only for use with the type of gas indi cated on the rating plate This appliance is not convert ible for use...

Страница 3: ...Have heater serviced Some people are more af fected by carbon monoxide than others These include pregnant women people with heart or lung disease or anemia those under the influ ence of alcohol and t...

Страница 4: ...or furniture 9 Do not use heater if any part has been under water Immediately call a qualified service technician to inspect the room heater and to replace any part of the control system and any gas c...

Страница 5: ...s Pressure inches of water Maximum 14 Maximum 14 Minimum 11 Minimum 11 Heater Weight 13 lbs 14 lbs Shipping Weight 16 lbs 17 lbs Heater Dimensions HxWxD 19 1 8 14 1 8 6 3 8 Carton Dimensions HxWxD 22...

Страница 6: ...er is damaged promptly inform dealer where you bought heater QUALIFIED INSTALLING AGENCY Only a qualified agency should install and replace gas piping gas utilization equipment or accessories and repa...

Страница 7: ...ibed in the National Fuel Gas Code ANSI Z223 1 NFPA 54 the International Fuel Gas Code or applicable local codes WARNING Iftheareainwhich theheatermaybeoperateddoes notmeettherequiredvolumefor indoorc...

Страница 8: ...Code ANSI Z223 1 NFPA 54 Air for Combustion and Ventilation for required size of ventilation grills or ducts IMPORTANT Do not provide openings for inlet or outlet air into attic if attic has a thermo...

Страница 9: ...in high traffic areas in windy or drafty areas Wheninstalledinabathroom do not use flammable products such as aerosol hair spray or any product that contains flam mable vapors Keep towels and other fl...

Страница 10: ...is no need to take out the two bulb clips 2 Take out the bulb clip from the hardware package and insert it into the square hole and then insert the sensing bulb into the bulb clip see Figure 5 Method...

Страница 11: ...Mounting Bracket attached to wall Horizontal Slots Stand Out Tab 12 1 8 14 1 2 Min 6 3 4 Min Adjoining Wall Only Insert Mounting Screws Through Last Hole On Each End Floor Marking Screw Locations 1 T...

Страница 12: ...s firmly secured to wall Do not over tighten Note Do not replace front panel at this time Replace front panel after making gas connec tions and checking for leaks CONNECTING TO PORTABLE CYLINDER GAS S...

Страница 13: ...tal position see Figure 14 This places the regulator vent in the proper position to protect it from the weather 6 Connect hose to heater inlet Tighten rmly using a wrench You must use the regulator s...

Страница 14: ...clude an equipment shutoff valve union and plugged 1 8 NPT tap Locate NPT tap within reach for test gauge hook up NPT tap must be upstream from heater see Figure 15 IMPORTANT Install an equipment shut...

Страница 15: ...ater and equipment shutoff valve to gas supply Check reconnected fittings for leaks Test Pressures Equal To or Less Than 1 2 PSIG 3 5 kPa 1 Close equipment shutoff valve see Fig ure 17 2 Pressurize su...

Страница 16: ...ol knob slightly and turn clockwise to the OFF position Note Knob cannot be turned from PILOT to OFF unless knob is pushed in slightly Do not force 4 Wait five 5 minutes to clear out any gas Then smel...

Страница 17: ...does not pop up when released contact a qualified service technician or gas supplier for repairs 6 With control knob pressed in push down and release ignitor button This will light pilot The pilot is...

Страница 18: ...n and off The thermostat used on this heater senses the room temperature At times the room may exceed the set temperature If so the burner will shut off The burner will cycle back on when room tempera...

Страница 19: ...rn and burner flame pattern often Incorrect flame patterns indicate the need for cleaning see Care and Maintenance page 20 or service WARNING Only a qualified service person should service and repair...

Страница 20: ...tore or home center may carry compressed air in a can You can use a vacuum cleaner in the blow position If using compressed air in a can please follow the directions on the can If you don t follow dir...

Страница 21: ...si tioned wrong Ignitor elec trode is broken 2 Ignitor electrode is not con nected to ignitor cable 3 Ignitor cable is pinched or wet 4 Broken ignitor cable 5 Bad piezo ignitor 1 Replace pilot assembl...

Страница 22: ...lace control valve Burner s does not light after ODS pilot is lit 1 Burner orifice is clogged 2 Burner orifice diameter is too small 3 Inlet gas pressure is too low 1 Clean burner orifice see Care and...

Страница 23: ...ng vapors from paint hair spray glues etc See IMPORTANT statement page 21 2 Gas leak See Warning State ment at the top of page 21 3 Low fuel supply propane LP gas only 1 Ventilate room Stop using odor...

Страница 24: ...www usaprocom com 200052 01B 24 PARTS MODEL ML100HBAHR 10 7 7 19 18 16 14 12 21 13 15 2 23 17 20 24 24 22 9 26 25 22 1 22 2 29 30 ODS Pilot Assembly 11 28 16 8 15 14 3 4 5 7 6 1 27...

Страница 25: ...ntrol Knob Assembly 1 12 NRV81FI 8 Pressure Regulator 1 13 ML079 01 Self Locking Screw 2 14 MB40034A Main Inlet Tube Assembly 1 15 MB40056 ODS Line Assembly 1 16 MB40054 Gas Outlet Tube Assembly 1 17...

Страница 26: ...www usaprocom com 200052 01B 26 PARTS MODEL ML100TBAHR 10 10 7 19 19 18 18 14 12 21 13 15 2 23 17 20 20 24 22 9 26 25 26 1 26 2 29 30 ODS Pilot Assembly 11 28 16 8 3 4 5 7 7 7 6 1 27...

Страница 27: ...0Z Screws 2 12 MB29003 Grill Guard 1 13 ML079 01 Self Locking Screw 2 14 ML084 03 Middle Panel 1 15 NRV81FI 8 Pressure Regulator 1 16 ML073 02 Ignitor Cable 1 17 161132 01 Mounting Bracket Assembly 1...

Страница 28: ...ories from your local dealer If they can not supply these acces sories contact ProCom Heating Inc at 1 866 573 0674 for information EQUIPMENT SHUTOFF VALVE For all models Equipment shutoff valve with...

Страница 29: ...ng Inc at 1 866 573 0674 When calling please have your model and serial numbers of your heater ready When Gas Pressure Is Too Low pilot will not stay lit burners will have delayed ignition fireplace w...

Страница 30: ..._____________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________...

Страница 31: ..._____________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________...

Страница 32: ...will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty IMPORTANT The heater MUST be installed by a qualified installer in accordance wit...

Отзывы: