Procom ML100HBAHR Скачать руководство пользователя страница 21

www.usaprocom.com

21

200052-01B

TROUBLESHOOTING

 WARNING: If you smell gas:

•  Shut off gas supply.

•  Do not try to light any appliance.

•  Do not touch any electrical switch; do not use any phone in your 

building.

•  Immediately call your gas supplier from a neighbor’s phone. Fol-

low the gas supplier’s instructions.

•  If you cannot reach your gas supplier, call the fire department.

 WARNING: Only a qualified service technician should service and 

repair heater. Make sure that power is turned off before proceeding. 

Turn off and let cool before servicing.

IMPORTANT:

 Operating heater where impurities in air exist may create odors. Cleaning sup

-

plies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., 

create fumes. These fumes may mix with combustion air and create odors.

Note: All troubleshooting items are listed in order of operation.

Problem

Possible Cause

Corrective Action

When  ignitor  button  is 

pressed  in,  there  is  no 

spark at ODS/pilot.

1. Ignitor  electrode  is  posi

-

tioned  wrong.  Ignitor  elec

-

trode is broken.

2. Ignitor electrode is not con

-

nected to ignitor cable.

3. Ignitor  cable  is  pinched  or 

wet.

4  Broken ignitor cable.

5. Bad piezo ignitor.

1. Replace pilot assembly.

2. Replace ignitor cable.

3. Free ignitor cable if pinched 

by any metal or tubing. Keep 

ignitor cable dry.

4. Replace ignitor cable.

5. Replace piezo ignitor.

When  ignitor  button  is 

pressed  in  there  is  a 

spark  at  ODS/pilot  but 

no ignition.

1. Gas supply is turned off or 

equipment  shutoff  valve  is 

closed.

2. Control  knob  not  fully 

pressed  in  while  pressing 

ignitor button.

3. Air  in  gas  lines  when  in

-

stalled.

4. ODS / pilot is clogged.

5. 

Incorrect inlet gas pressure 

or inlet regulator is damaged.

6. Control  knob  not  in  PILOT 

position.

7. Depleted  gas  supply  (pro

-

pane).

1. Turn on gas supply or open 

equipment shutoff valve.

2. Fully  press  in  control  knob 

while pressing ignitor button.

3. Continue holding down con

-

trol knob. Repeat igniting op

-

eration until air is removed.

4. 

Clean  ODS/pilot  (see 

Care 

and Maintenance

, page 20) or 

replace ODS/pilot assembly.

5. 

Check inlet gas pressure or 

replace inlet gas regulator.

6. Turn control knob to PILOT 

position.

7. Contact  local  propane/LP 

gas company.

Содержание ML100HBAHR

Страница 1: ...life Do not store or use gasoline or other flammable va pors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any e...

Страница 2: ...ently located manufactured mobile home where not prohibited by local codes This appliance is only for use with the type of gas indi cated on the rating plate This appliance is not convert ible for use...

Страница 3: ...Have heater serviced Some people are more af fected by carbon monoxide than others These include pregnant women people with heart or lung disease or anemia those under the influ ence of alcohol and t...

Страница 4: ...or furniture 9 Do not use heater if any part has been under water Immediately call a qualified service technician to inspect the room heater and to replace any part of the control system and any gas c...

Страница 5: ...s Pressure inches of water Maximum 14 Maximum 14 Minimum 11 Minimum 11 Heater Weight 13 lbs 14 lbs Shipping Weight 16 lbs 17 lbs Heater Dimensions HxWxD 19 1 8 14 1 8 6 3 8 Carton Dimensions HxWxD 22...

Страница 6: ...er is damaged promptly inform dealer where you bought heater QUALIFIED INSTALLING AGENCY Only a qualified agency should install and replace gas piping gas utilization equipment or accessories and repa...

Страница 7: ...ibed in the National Fuel Gas Code ANSI Z223 1 NFPA 54 the International Fuel Gas Code or applicable local codes WARNING Iftheareainwhich theheatermaybeoperateddoes notmeettherequiredvolumefor indoorc...

Страница 8: ...Code ANSI Z223 1 NFPA 54 Air for Combustion and Ventilation for required size of ventilation grills or ducts IMPORTANT Do not provide openings for inlet or outlet air into attic if attic has a thermo...

Страница 9: ...in high traffic areas in windy or drafty areas Wheninstalledinabathroom do not use flammable products such as aerosol hair spray or any product that contains flam mable vapors Keep towels and other fl...

Страница 10: ...is no need to take out the two bulb clips 2 Take out the bulb clip from the hardware package and insert it into the square hole and then insert the sensing bulb into the bulb clip see Figure 5 Method...

Страница 11: ...Mounting Bracket attached to wall Horizontal Slots Stand Out Tab 12 1 8 14 1 2 Min 6 3 4 Min Adjoining Wall Only Insert Mounting Screws Through Last Hole On Each End Floor Marking Screw Locations 1 T...

Страница 12: ...s firmly secured to wall Do not over tighten Note Do not replace front panel at this time Replace front panel after making gas connec tions and checking for leaks CONNECTING TO PORTABLE CYLINDER GAS S...

Страница 13: ...tal position see Figure 14 This places the regulator vent in the proper position to protect it from the weather 6 Connect hose to heater inlet Tighten rmly using a wrench You must use the regulator s...

Страница 14: ...clude an equipment shutoff valve union and plugged 1 8 NPT tap Locate NPT tap within reach for test gauge hook up NPT tap must be upstream from heater see Figure 15 IMPORTANT Install an equipment shut...

Страница 15: ...ater and equipment shutoff valve to gas supply Check reconnected fittings for leaks Test Pressures Equal To or Less Than 1 2 PSIG 3 5 kPa 1 Close equipment shutoff valve see Fig ure 17 2 Pressurize su...

Страница 16: ...ol knob slightly and turn clockwise to the OFF position Note Knob cannot be turned from PILOT to OFF unless knob is pushed in slightly Do not force 4 Wait five 5 minutes to clear out any gas Then smel...

Страница 17: ...does not pop up when released contact a qualified service technician or gas supplier for repairs 6 With control knob pressed in push down and release ignitor button This will light pilot The pilot is...

Страница 18: ...n and off The thermostat used on this heater senses the room temperature At times the room may exceed the set temperature If so the burner will shut off The burner will cycle back on when room tempera...

Страница 19: ...rn and burner flame pattern often Incorrect flame patterns indicate the need for cleaning see Care and Maintenance page 20 or service WARNING Only a qualified service person should service and repair...

Страница 20: ...tore or home center may carry compressed air in a can You can use a vacuum cleaner in the blow position If using compressed air in a can please follow the directions on the can If you don t follow dir...

Страница 21: ...si tioned wrong Ignitor elec trode is broken 2 Ignitor electrode is not con nected to ignitor cable 3 Ignitor cable is pinched or wet 4 Broken ignitor cable 5 Bad piezo ignitor 1 Replace pilot assembl...

Страница 22: ...lace control valve Burner s does not light after ODS pilot is lit 1 Burner orifice is clogged 2 Burner orifice diameter is too small 3 Inlet gas pressure is too low 1 Clean burner orifice see Care and...

Страница 23: ...ng vapors from paint hair spray glues etc See IMPORTANT statement page 21 2 Gas leak See Warning State ment at the top of page 21 3 Low fuel supply propane LP gas only 1 Ventilate room Stop using odor...

Страница 24: ...www usaprocom com 200052 01B 24 PARTS MODEL ML100HBAHR 10 7 7 19 18 16 14 12 21 13 15 2 23 17 20 24 24 22 9 26 25 22 1 22 2 29 30 ODS Pilot Assembly 11 28 16 8 15 14 3 4 5 7 6 1 27...

Страница 25: ...ntrol Knob Assembly 1 12 NRV81FI 8 Pressure Regulator 1 13 ML079 01 Self Locking Screw 2 14 MB40034A Main Inlet Tube Assembly 1 15 MB40056 ODS Line Assembly 1 16 MB40054 Gas Outlet Tube Assembly 1 17...

Страница 26: ...www usaprocom com 200052 01B 26 PARTS MODEL ML100TBAHR 10 10 7 19 19 18 18 14 12 21 13 15 2 23 17 20 20 24 22 9 26 25 26 1 26 2 29 30 ODS Pilot Assembly 11 28 16 8 3 4 5 7 7 7 6 1 27...

Страница 27: ...0Z Screws 2 12 MB29003 Grill Guard 1 13 ML079 01 Self Locking Screw 2 14 ML084 03 Middle Panel 1 15 NRV81FI 8 Pressure Regulator 1 16 ML073 02 Ignitor Cable 1 17 161132 01 Mounting Bracket Assembly 1...

Страница 28: ...ories from your local dealer If they can not supply these acces sories contact ProCom Heating Inc at 1 866 573 0674 for information EQUIPMENT SHUTOFF VALVE For all models Equipment shutoff valve with...

Страница 29: ...ng Inc at 1 866 573 0674 When calling please have your model and serial numbers of your heater ready When Gas Pressure Is Too Low pilot will not stay lit burners will have delayed ignition fireplace w...

Страница 30: ..._____________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________...

Страница 31: ..._____________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________...

Страница 32: ...will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty IMPORTANT The heater MUST be installed by a qualified installer in accordance wit...

Отзывы: