Procom ML100HBAHR Скачать руководство пользователя страница 16

www.usaprocom.com

200052-01B

16

OFF

HIGH

LOW

PILOT/IGN

OPERATION

FOR YOUR SAFETY READ BEFORE LIGHTING

 WARNING: If you do not fol-

low these instructions exactly, a 

fire or  explosion may result caus-

ing property damage, personal 

injury or loss of life.

A.  This appliance has a pilot which must 

be lighted by hand. When lighting the 

pilot, follow these instructions exactly.

B.  BEFORE LIGHTING smell all around the 

appliance area for gas. Be sure to smell 

next to the floor because some gas is 

heavier than air and will settle on the floor.

 

WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.

• Do not touch any electric switch; do 

not use any phone in your building.

• Immediately call your gas supplier 

from a neighbor’s phone. Follow the 

gas supplier’s instructions.

• If you cannot reach your gas supplier, 

call the fire department.

C.  Use only your hand to push in or turn 

the gas control knob. Never use tools. 

If the knob will not push in or turn by 

hand, don’t try to repair it, call a qualified 

service technician. Force or attempted 

repair may result in a fire or explosion.

D.  Do not use this appliance if any part 

has been under water. Immediately call 

a qualified service technician to inspect 

the appliance and to replace any part of 

the control system and any gas control 

which has been under water.

MANUAL CONTROL MODEL ML100HBAHR

LIGHTING INSTRUCTIONS

1.  STOP! Read the safety information above.
2.  Check that gas supply to heater is on.
3.  Push in gas control knob slightly and turn 

clockwise 

 to the OFF position.

Note: Knob cannot be turned from PILOT to 

OFF  unless  knob  is  pushed  in  slightly.  Do 

not force.

4.  Wait five (5) minutes to clear out any gas. 

Then  smell  for  gas,  including  near  the 

floor. If you smell gas, STOP! Follow "B" 

in the safety information above. If you do 

not smell gas, go to the next step.

5.  Push in gas control knob slightly and turn 

counterclockwise 

  to  PILOT/IGN 

and press for five (5) seconds

 

Note: The first time that the heater is oper-

ated after connecting the gas supply, the 

control knob should be pressed for about 

thirty (30) seconds. This will allow air to 

bleed from the gas system.

6.  With control knob pressed in, push down 

and  release  the  ignitor  button. This  will 

light pilot. If needed, keep pressing ignitor 

button until pilot lights.

7.  Keep  control  knob  pressed  in  for  30 

seconds  after  lighting  pilot. After  30 

seconds, release control knob. If control 

knob  does  not  pop  up  when  released, 

contact a qualified service technician or 

gas supplier for repairs.

 

Note:  If  pilot  goes  out,  repeat  steps  3 

through 7. This heater has a safety inter-

lock system. Wait one (1) minute before 

lighting pilot again.

8.  To select the desired heating level, partially 

press down the control knob slightly and 

turn  counterclockwise 

. Release 

downward  pressure  on  the  knob  while 

continuing  to  turn  until  the  knob  locks 

at the desired setting. The main burner 

should light. Set control knob to the de

-

sired heating position.

 

Note:  Both  HIGH  and  LOW  are  locked 

positions. You must press in the control 

knob before turning it from these positions.

Figure 19 - Control Knob in the OFF 

Position

Ignitor Button

Control Knob

Содержание ML100HBAHR

Страница 1: ...life Do not store or use gasoline or other flammable va pors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any e...

Страница 2: ...ently located manufactured mobile home where not prohibited by local codes This appliance is only for use with the type of gas indi cated on the rating plate This appliance is not convert ible for use...

Страница 3: ...Have heater serviced Some people are more af fected by carbon monoxide than others These include pregnant women people with heart or lung disease or anemia those under the influ ence of alcohol and t...

Страница 4: ...or furniture 9 Do not use heater if any part has been under water Immediately call a qualified service technician to inspect the room heater and to replace any part of the control system and any gas c...

Страница 5: ...s Pressure inches of water Maximum 14 Maximum 14 Minimum 11 Minimum 11 Heater Weight 13 lbs 14 lbs Shipping Weight 16 lbs 17 lbs Heater Dimensions HxWxD 19 1 8 14 1 8 6 3 8 Carton Dimensions HxWxD 22...

Страница 6: ...er is damaged promptly inform dealer where you bought heater QUALIFIED INSTALLING AGENCY Only a qualified agency should install and replace gas piping gas utilization equipment or accessories and repa...

Страница 7: ...ibed in the National Fuel Gas Code ANSI Z223 1 NFPA 54 the International Fuel Gas Code or applicable local codes WARNING Iftheareainwhich theheatermaybeoperateddoes notmeettherequiredvolumefor indoorc...

Страница 8: ...Code ANSI Z223 1 NFPA 54 Air for Combustion and Ventilation for required size of ventilation grills or ducts IMPORTANT Do not provide openings for inlet or outlet air into attic if attic has a thermo...

Страница 9: ...in high traffic areas in windy or drafty areas Wheninstalledinabathroom do not use flammable products such as aerosol hair spray or any product that contains flam mable vapors Keep towels and other fl...

Страница 10: ...is no need to take out the two bulb clips 2 Take out the bulb clip from the hardware package and insert it into the square hole and then insert the sensing bulb into the bulb clip see Figure 5 Method...

Страница 11: ...Mounting Bracket attached to wall Horizontal Slots Stand Out Tab 12 1 8 14 1 2 Min 6 3 4 Min Adjoining Wall Only Insert Mounting Screws Through Last Hole On Each End Floor Marking Screw Locations 1 T...

Страница 12: ...s firmly secured to wall Do not over tighten Note Do not replace front panel at this time Replace front panel after making gas connec tions and checking for leaks CONNECTING TO PORTABLE CYLINDER GAS S...

Страница 13: ...tal position see Figure 14 This places the regulator vent in the proper position to protect it from the weather 6 Connect hose to heater inlet Tighten rmly using a wrench You must use the regulator s...

Страница 14: ...clude an equipment shutoff valve union and plugged 1 8 NPT tap Locate NPT tap within reach for test gauge hook up NPT tap must be upstream from heater see Figure 15 IMPORTANT Install an equipment shut...

Страница 15: ...ater and equipment shutoff valve to gas supply Check reconnected fittings for leaks Test Pressures Equal To or Less Than 1 2 PSIG 3 5 kPa 1 Close equipment shutoff valve see Fig ure 17 2 Pressurize su...

Страница 16: ...ol knob slightly and turn clockwise to the OFF position Note Knob cannot be turned from PILOT to OFF unless knob is pushed in slightly Do not force 4 Wait five 5 minutes to clear out any gas Then smel...

Страница 17: ...does not pop up when released contact a qualified service technician or gas supplier for repairs 6 With control knob pressed in push down and release ignitor button This will light pilot The pilot is...

Страница 18: ...n and off The thermostat used on this heater senses the room temperature At times the room may exceed the set temperature If so the burner will shut off The burner will cycle back on when room tempera...

Страница 19: ...rn and burner flame pattern often Incorrect flame patterns indicate the need for cleaning see Care and Maintenance page 20 or service WARNING Only a qualified service person should service and repair...

Страница 20: ...tore or home center may carry compressed air in a can You can use a vacuum cleaner in the blow position If using compressed air in a can please follow the directions on the can If you don t follow dir...

Страница 21: ...si tioned wrong Ignitor elec trode is broken 2 Ignitor electrode is not con nected to ignitor cable 3 Ignitor cable is pinched or wet 4 Broken ignitor cable 5 Bad piezo ignitor 1 Replace pilot assembl...

Страница 22: ...lace control valve Burner s does not light after ODS pilot is lit 1 Burner orifice is clogged 2 Burner orifice diameter is too small 3 Inlet gas pressure is too low 1 Clean burner orifice see Care and...

Страница 23: ...ng vapors from paint hair spray glues etc See IMPORTANT statement page 21 2 Gas leak See Warning State ment at the top of page 21 3 Low fuel supply propane LP gas only 1 Ventilate room Stop using odor...

Страница 24: ...www usaprocom com 200052 01B 24 PARTS MODEL ML100HBAHR 10 7 7 19 18 16 14 12 21 13 15 2 23 17 20 24 24 22 9 26 25 22 1 22 2 29 30 ODS Pilot Assembly 11 28 16 8 15 14 3 4 5 7 6 1 27...

Страница 25: ...ntrol Knob Assembly 1 12 NRV81FI 8 Pressure Regulator 1 13 ML079 01 Self Locking Screw 2 14 MB40034A Main Inlet Tube Assembly 1 15 MB40056 ODS Line Assembly 1 16 MB40054 Gas Outlet Tube Assembly 1 17...

Страница 26: ...www usaprocom com 200052 01B 26 PARTS MODEL ML100TBAHR 10 10 7 19 19 18 18 14 12 21 13 15 2 23 17 20 20 24 22 9 26 25 26 1 26 2 29 30 ODS Pilot Assembly 11 28 16 8 3 4 5 7 7 7 6 1 27...

Страница 27: ...0Z Screws 2 12 MB29003 Grill Guard 1 13 ML079 01 Self Locking Screw 2 14 ML084 03 Middle Panel 1 15 NRV81FI 8 Pressure Regulator 1 16 ML073 02 Ignitor Cable 1 17 161132 01 Mounting Bracket Assembly 1...

Страница 28: ...ories from your local dealer If they can not supply these acces sories contact ProCom Heating Inc at 1 866 573 0674 for information EQUIPMENT SHUTOFF VALVE For all models Equipment shutoff valve with...

Страница 29: ...ng Inc at 1 866 573 0674 When calling please have your model and serial numbers of your heater ready When Gas Pressure Is Too Low pilot will not stay lit burners will have delayed ignition fireplace w...

Страница 30: ..._____________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________...

Страница 31: ..._____________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________...

Страница 32: ...will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty IMPORTANT The heater MUST be installed by a qualified installer in accordance wit...

Отзывы: