background image

30,000 BTU/Hr 

Model Shown

VENT-FREE GAS WALL 

HEATER

OWNER’S OPERATION AND 

INSTALLATION MANUAL

BLUE FLAME MODELS

LRT10B-LP, LRT10B-NG

LRT20B-LP, LRT20B-NG

LRT30B-LP, LRT30B-NG

 

WARNING: If the information in this manual is not 

followed exactly, a fire or explosion may result causing 

property damage, personal injury or loss of life.
—  Do not store or use gasoline or other  flammable va-

pors and liquids in the  vicinity of this or any other 

appliance.

—  WHAT TO DO IF YOU SMELL GAS

•  Do not try to light any appliance.

•  Do not touch any electrical switch; do not use any 

phone in your building.

•  Immediately call your gas supplier from a neighbor’s 

phone. Follow the gas supplier’s instructions.

•  If you cannot reach your gas supplier, call the fire 

department.

—  Installation and service must be performed by a quali-

fied installer, service agency or the gas supplier.

INSTALLER: Leave this manual with the appliance.

CONSUMER: Retain this manual for future reference.

Questions, problems, missing parts? 

Before returning to your retailer, call 

our customer service department at 1-866-573-0674, 7:30 am - 4:15 pm CST, 

Monday through Friday or email

 [email protected]

Содержание LOST Piver LRT10B-LP

Страница 1: ...o not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructi...

Страница 2: ...920 7 967 006 7 967 007 7 654 820 7 730 765 7 677 236 7 607 426 7 434 447 This is an unvented gas fired heater It uses air oxygen from the room in which it is installed Provisions for ad equatecombust...

Страница 3: ...than others These include pregnant women people with heart or lung disease or anemia those under the influ ence of alcohol and those at high altitudes NATURALAND PROPANE LP GAS Natural and Propane LP...

Страница 4: ...r off If heated the vapors from these prod ucts may create a white powder residue within burner box or on adjacent walls or furniture 8 Do not use heater if any part has been under water Immediately c...

Страница 5: ...T20B LP Ignition Piezo Piezo Gas Type Natural Propane LP Maximum Input Rating 20 000 BTU Hr 20 000 BTU Hr Minimum Input Rating 10 000 BTU Hr 10 000 BTU Hr Pressure Regulator Setting 4 W C 9 W C Inlet...

Страница 6: ...Inc 1 Batterymarch Park Quincy MA 02269 9101 This heater is designed for vent free op eration State and local codes in some areas prohibit the use of vent free heaters State of Massachusetts The insta...

Страница 7: ...e combustion and ventilation air Read the following instructionstoinsureproperfresh air for this and other fuel burning appliances in your home Today s homes are built more energy efficient than ever...

Страница 8: ...n grills or ducts You must provide two perma nent openings one within 12 of the ceiling and one within 12 of the floor Connect these items directly to the outdoors or spaces open to the outdoors These...

Страница 9: ...walls to discolor Figure 4 Mounting Clearances as Viewed From Front of Heater IMPORTANT Vent free heaters add moisture to the air Although this is beneficial installing heater in rooms without enough...

Страница 10: ...ping Remove mounting bracket from back panel Methods For Attaching Mounting Bracket To Wall Use only the last hole on each end of mount ing bracket to attach bracket to wall Attach mounting bracket to...

Страница 11: ...tened to wall studs Attaching to Wall Anchor Method For attaching mounting bracket to hollow walls wall areas between studs or solid walls concrete or masonry 1 Drill holes at marked locations using 5...

Страница 12: ...Bottom Mounting Screws Placing Heater On Mounting Bracket 1 Locate two horizontal slots on back panel of heater see Figure 10 2 Place heater onto mounting bracket Slide horizontal slots onto stand ou...

Страница 13: ...ator between the heater and gassupply Gassupplierprovides externalregulatorfornaturalgas Theinstallerprovidestheexternal regulator for propane LP gas CAUTION Avoid damage to regulator Hold gas regulat...

Страница 14: ...valves The installer must supply an external regula tor The external regulator will reduce incom ing gas pressure You must reduce incoming gas pressure to between 11 and 14 of water If you do not red...

Страница 15: ...upply piping system Apply mixture of liquid soap and water to gas joints If bubbles form there may be a leak 5 Correct all leaks at once 6 Reconnect heater and equipment shutoff valve to gas supply Ch...

Страница 16: ...electric switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the f...

Страница 17: ...one 1 minute before lighting pilot again 8 Turn control knob counterclockwise to desired heating level The main burner should light Set control knob to any heat level between HI and LO CAUTION Do not...

Страница 18: ...20 Incorrect Pilot Flame Pattern IMPORTANT Owner s should check pilot flame pattern and burner flame pattern often Incorrect flame patterns indicate the need for cleaning see Care and Maintenance pag...

Страница 19: ...move four screws securing front panel 3 Pull front panel forward 4 Inspect burner and pilot for dust and dirt 5 Blow air through the ports slots and holes in the burner 6 Replace front panel using scr...

Страница 20: ...itor button 3 Continue holding down con trol knob Repeat igniting op eration until air is removed 4 Clean ODS pilot see Care and Maintenance page 19 or replace ODS pilot assembly 5 Check inlet gas pre...

Страница 21: ...DS pilot is lit 1 Burner orifice is clogged 2 Inlet gas pressure is too low 1 Clean burner orifice see Care and Maintenance page 19 2 Contact local gas supplier Delayed ignition of burner s 1 Manifold...

Страница 22: ...un wanted odors 1 Heater is burning vapors from paint hair spray glues etc See IMPORTANTstatement page20 2 Gas leak See Warning State ment at the top of page 20 3 Low fuel supply propane LP gas only...

Страница 23: ...defective part to the factory PARTS NOT UNDER WARRANTY Contact authorized dealers of this product If they can t supply original replacement part s call Customer Service toll free at 1 866 573 0674 fo...

Страница 24: ...www usaprocom com 200403 01A 24 2 11 3 7 1 8 10 5 6 4 12 9 14 13 15 PARTS MODELS LRT10B NG AND LRT10B LP...

Страница 25: ...Piezo Ignitor 1 4 161130 01 161130 01 Thermostat Valve 1 5 Burner Assembly 1 6 162332 03 ODS Pilot Natural Gas 1 162332 01 ODS Pilot Propane LP Gas 1 7 RV81FIL 4 RV81FIL 9 Regulator 1 8 Cabinet Brack...

Страница 26: ...www usaprocom com 200403 01A 26 2 11 3 1 8 10 6 12 7 5 4 Thermostat Valve 14 13 15 9 PARTS MODELS LRT20B NG LRT20B LP LRT30B NG LRT30B LP 20 000 BTU Hr Model Shown...

Страница 27: ...161130 01 161130 01 Thermostat Valve 1 5 Burner Assembly 1 6 162332 04 162332 04 ODS Pilot NG 1 162332 02 162332 02 ODS Pilot LP 1 7 RV81FIL 4 RV81FIL 9 RV81FIL 4 RV81FIL 9 Regulator 1 8 Cabinet Brac...

Страница 28: ...will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty IMPORTANT The heater MUST be installed by a qualified installer in accordance wit...