82
1
2
3
F1
Switched
F2
Switched
F3
Switched
F4
Switched
F5
Switched
F6
Switched
F7
Switched
F8
Switched
F9
Constant
F10
Constant
F11
Constant
F12
Constant
F13
Switched
F14
Switched
F15
Switched
F16
Switched
F17
Switched
F18
Switched
F19
Switched
F20
Switched
F21
Switched
F22
Selector Fuse
F23
"Connect Two"
F24
V+ Switched
F25
V- Switched
F26
Selector Fuse
F27
Selector Fuse
AF28
5V
Switched
AF29
8.5V
Switched
AF30
5-12V
Switched
F31
F32
F33
F34
Selector Fuse
AF4
Switched
AF5
Switched
AF6
Switched
AF7
Switched
AF8
Switched
AF9
Switched
Black End
Striped End
Fuse Descriptions
X2-CAN 2 V-
X2-CAN 2 V+
Terminals
Component
Description of Purpose
Additional Componenets
X7-1
X7-2
X7-3
X7-4
X7-7
X7-8
PLC Programing network resistor
J1939 network resistor
CANOpen network resistor
Voltage spike surge protector
120 Ohm 1/4 Watt Resistor
120 Ohm 1/4 Watt Resistor
120 Ohm 1/4 Watt Resistor
TVS Diode
Aux Supply
Aux Supply
Aux Supply
Aux Supply
Aux Supply
Only
One
of the
three slots should
have a Fuse.
Admix 4 Flow Meter Selection
Extra E-Stop (No, Yes)
Admix 1 Flow Meter Selection
Admix 2 Flow Meter Selection
Admix 3 Flow Meter Selection
J1939 Network Supply
I/O #1 (Hydraulic Controls #1)
I/O #2 (Hydraulic Controls #2)
I/O #3 (Flow Meters)
Printer
Display Box
Water Flow Meter Selection
Charge Cradle
PLC Supply
PLC Supply (Outputs #1)
PLC Supply (Outputs #2)
PLC Supply (Outputs #3)
PLC Supply (Outputs #4)
PLC Aux Power
Supplies
Cooler Fan Type Selector (Brushless,
Brushed)
Selector Fuse
Autolube (Option)
RPM V+
High Level Cement Aux (Option)
Water Heat Exchanger (Option)
Cooler #1
Cooler #2
Selector Fuse
RPM type selector
(Determined by
the Truck)
Spare Relay #1
Spare Relay #2
Work Lights (Display Box Sw. Opt.)
Display Box Screen
Fuse Position
Fuse
Label
Constant,
Switched or
Selector fuse
Description
13.
ELECTRICAL
13.1 RELAY AND FUSE REPLACEMENT
IMPORTANT!
All relay and fuse information are printed on the mixer circuit board and can also be found in the circuit board
schematics in the appendices.
The main power fuse is bolted directly to the battery
post. There is a spare fuse inside the main power box on
the side of the mixer body.
Inside the main power box there is also a fuse chart as
shown that itemizes the fuse numbers and use.
Some fuses are used as selectors based on the functions
wiring setup. Be careful not to mix up the positions should
one of these fuses be removed.
A
A
Содержание P Series
Страница 1: ...1 PROALL Mobile Mixer Service Manual P Model MX04703 August 2020 Rev 1 0 ...
Страница 2: ...2 5810 47 Avenue Olds Alberta Canada T4H 1V1 E info proallinc com P 403 335 9500 F 403 335 9560 ...
Страница 20: ...20 has been removed and not replaced then the charge pressure will drop to zero C ...
Страница 85: ...International Manufacturing Inc P P1 OUT IN OUT IN 2 1 3 IN S1 S2 2 1 3 OUT IN ...
Страница 100: ... ADMIX 1 ADMIX 2 WORK LIGHTS ...
Страница 101: ... COOLER 1 VIB1 SPARE VIB1A SPARE VIB2A VIB2 VIB3 VIB4 VIB5 ...
Страница 105: ... BATTERY V BATTERY V ...