12.5 OIL LEVEL
WARNING!
Operating the hydraulic system without enough oil in the reservoir will cause permanent damage to hydraulic
pumps.
Cold oil level should not go above the top black line on the
reservoir sight glass . Enough air space must be left in
the reservoir to allow for oil expansion when at operating
temperature.
A low oil level switch is be used to monitor a low oil
condition and generate an alarm, which will turn off the
trucks PTO.
12.6 OIL COOLER
WARNING!
The hydraulic oil cooler operation is critical in ensuring oil temperature is keep under 70°C (160°F). Ensure
cooler core is not plugged with debris and fans are running. If oil temperature rises abnormally or is going into
temperature alarm check to ensure fans are on.
12.6.1 FAN FUSES
Oil cooler fans can be turned on manually on the Mixer
Settings screen by pressing “Cooler ON”. This is a good tool
to troubleshooting fan operation and for blown fuses.
The oil cooler has two fans that have separate fuses located
at F5 and F6 .
If a new fuse continues to blow, then the oil cooler fan may
be shorted or jammed (see removal and replacement).
A
B
A
B
A
A
B
B
Содержание P Series
Страница 1: ...1 PROALL Mobile Mixer Service Manual P Model MX04703 August 2020 Rev 1 0 ...
Страница 2: ...2 5810 47 Avenue Olds Alberta Canada T4H 1V1 E info proallinc com P 403 335 9500 F 403 335 9560 ...
Страница 20: ...20 has been removed and not replaced then the charge pressure will drop to zero C ...
Страница 85: ...International Manufacturing Inc P P1 OUT IN OUT IN 2 1 3 IN S1 S2 2 1 3 OUT IN ...
Страница 100: ... ADMIX 1 ADMIX 2 WORK LIGHTS ...
Страница 101: ... COOLER 1 VIB1 SPARE VIB1A SPARE VIB2A VIB2 VIB3 VIB4 VIB5 ...
Страница 105: ... BATTERY V BATTERY V ...