11.3 FLOW METER CLEANING AND REPLACEMENT
IMPORTANT!
The same buildup that occurs on the strainer can also over time build up on the inside of the flow meter, which
will cause the flow meter to stop reading. Flushing the admix system with water weekly will help prevent this
buildup.
To remove the flow meter, uncouple union fitting and
remove the hose and gear clamp.
Disconnect the electrical wire. If removing more than one
flow meter for cleaning be careful not to mix up the wires
when re-installing.
To clean the flow meter run a non-metal pipe cleaner
through the flow meter several times to clean any debris or
build-up inside the flow meter.