52
Figure 20. Install bearing with grease fitting to the right
6.
Install the bearing bolts through the bearing, auger seal and bearing seal assembly, lightly compressing the
auger seal next to the bearing.
7.
Tighten the bearing collar by hand then using a collar wrench or punch and mallet, tighten the collar until the
collar meets resistance then turn the collar another ¼ turn. Tighten the bearing collar set screw.
8.
Install a 45 degree pipe fitting on the bearing and auger seal and 90 degree fitting in the bottom of the mix
auger frame.
9.
Install three grease hoses (PN 189112) into the three pipe fittings and install in the grease hose mount bracket
(PN MX01373) in the order they are installed on the seal assembly; the upper most hose being the hose
attached to the mix auger frame and lowest hose attached to the bearing.
10.
Install a coupling (PN 196198) on each grease hose then a grease nipple (PN 189001) on each hose.
Important: Be careful to install the coupling with a small amount of torque as the grease hose fittings may split when too
much torque is applied.
6.4 TOP MOTOR, BEARING AND DRIVE SHAFT REMOVAL
Note: To make removal easier, support the auger screw with a crane or other lifting device throughout the following
procedure.
1.
Remove the top shield (PN MX01846) and bottom shield (PN MX01795) from the offset bracket (PN MX10006)
2.
Remove bolts holding the hydraulic motor mount plate (PN MX01803) to the offset bracket. Retain the
compression springs (PN 347212).
3.
Remove the splined coupling (PN MX00017).
4.
Loosen the two set screws from the bearing (PN AGBR004A) and using a collar wrench or punch and mallet,
loosen the collar from the bearing.
5.
Slide the bearing off the auger drive shaft (PN MX01389).
6.
Remove the bolts holding the drive shaft to the auger. This may require the bolts be cut.
7.
Remove the drive shaft.
8.
Remove bolts holding the offset bracket to the mix auger frame and remove offset bracket.
6.5 TOP MOTOR, BEARING AND DRIVE SHAFT INSTALLATION
Note: To make removal easier, support the auger screw with a crane or other lifting device throughout the following
procedures.
Содержание P Series
Страница 1: ...1 PROALL Mobile Mixer Service Manual P Model MX04703 August 2020 Rev 1 0 ...
Страница 2: ...2 5810 47 Avenue Olds Alberta Canada T4H 1V1 E info proallinc com P 403 335 9500 F 403 335 9560 ...
Страница 20: ...20 has been removed and not replaced then the charge pressure will drop to zero C ...
Страница 85: ...International Manufacturing Inc P P1 OUT IN OUT IN 2 1 3 IN S1 S2 2 1 3 OUT IN ...
Страница 100: ... ADMIX 1 ADMIX 2 WORK LIGHTS ...
Страница 101: ... COOLER 1 VIB1 SPARE VIB1A SPARE VIB2A VIB2 VIB3 VIB4 VIB5 ...
Страница 105: ... BATTERY V BATTERY V ...