background image

 

 

 

OCC-CWDM-301-18

 

S

ERIES

 

Optical Channel Checker 

Operation Guide

 

Содержание OCC-CWDM-301-18A

Страница 1: ...OCC CWDM 301 18 SERIES Optical Channel Checker Operation Guide...

Страница 2: ...afety instructions Not taking any safety precautions or following the instructions will violate the safety standards of design manufacturing and application of these instruments In no case will the Pr...

Страница 3: ...no laser beam in the fiber before testing via OTDR Otherwise it may result in imprecise test trace even permanent damage for the OTDR Caution Battery Battery for this instrument is rechargeable NiMH...

Страница 4: ...ement Application of OTDR 13 3 3 1 Measurement Contents of OTDR 13 3 3 2 Trace Analysis of OTDR 13 3 4 Trace Display Screen of OTDR 13 3 4 1 Trace Display of OTDR 14 3 4 2 Information Window of OTDR 1...

Страница 5: ...Zoom out Trace Horizontally 38 4 6 Zoom in Trace Vertically 38 4 7 Zoom out Trace Vertically 38 4 8 Re analyze the trace 38 4 9 Save Trace 39 4 10 Browse Saved Traces 40 4 11 Upload Saved Traces 40 4...

Страница 6: ...e reshipment becomes necessary 1 2 Unpacking and Inspection This instrument has been carefully packed in accordance with standard shipping procedures Examine the instrument for damage that may have oc...

Страница 7: ...size lightweight and easy to use CE FCC certificates Result display in histogram and list Straightforward result display for easy understanding Internal clock fiber S N editable Internal clock enables...

Страница 8: ...aff of our company or representatives 2 2 Instrument Interfaces Instructions Figure 2 1 Coping of OTDR AC Power Jack Power adapter jack requirements 13 8V DC 1 2A Data Transfer Port For all types ther...

Страница 9: ...batteries in case of excessive discharging The inside batteries should be recharged immediately through adapter Please charge only when battery remaining capacity is low or adapter should be unplugged...

Страница 10: ...om out or zoom in trace vertically Select parameter to be adjusted in parameter configuration Move marker leftwards or rightwards in Trace operation Turn page while in Help sub menu Together with Shif...

Страница 11: ...relating to length Information relating to distance is obtained through time information that s the reason why there is time Domain in the name of OTDR Fresnel reflection occurs at the boundary betwe...

Страница 12: ...When non reflection event occurs a power decline shows on trace as in Figure 3 2 Figure 3 2 Non reflection Event 3 2 1 3 Inspection Events OTDR sends off a light pulse into the optic fiber to be inspe...

Страница 13: ...de of reflection Auto measurement of cumulative loss of a single event 3 3 2 Trace Analysis of OTDR The trace analysis of OTDR is fully automatic The trace locates Reflection events of connections and...

Страница 14: ...e x axis stands for distance as shown in Figure 3 4 Reflection Attenuation Relative power Distance Figure 3 4 Traces and Coordinates 3 4 2 Information Window of OTDR Contents of this window measuremen...

Страница 15: ...ion of events inspected Any defined posts will be displayed in event list for example non reflection event like welding points and reflection event like connectors as shown in Figure 3 6 Figure 3 6 Ev...

Страница 16: ...etween marker A and B When you change either marker record will change accordingly A B Distance between two markers 2 points loss Loss between two markers power difference between two markers 2 points...

Страница 17: ...rizontally Zoom out trace horizontally Zoom in trace vertically Zoom out trace vertically B A Switching between markers Review events list upwards Review events list downwards Battery power indicator...

Страница 18: ...trc 15 20 1 4666 1550 nm Wavelength B A 30s 80 km 2500 ns R a n g e W a v e l e n g t h 1550 nm P u l s e W i d t h Auto A v g T i m e 30s I O R 1 4666 N r e f l T h r e 0 20 dB R e f l T h r e 52 00...

Страница 19: ...laser Scatter Coefficient Which affects backward scatter power of laser in fiber Non reflection threshold Events whose insertion loss is greater than the threshold displays here Reflection threshold...

Страница 20: ...resolution and smaller dead zone however the dynamic range will be decreased On the contrary wide pulse width can bring higher dynamic range and measure comparatively long distance but resolution and...

Страница 21: ...ally become Auto 30 s 80 km 1 4666 2500 ns 1550 nm Ave Time Range IOR Pulsewidth Wavelength 8Km Div 3 50 dB Div trace1 trc 15 20 B A 30 s 80km 2500 ns R a n g e W a v e l e n g t h 1550 nm P u l s e W...

Страница 22: ...d to highlight wavelength press Enter to change wavelength as shown in Figure 3 13 Figure 3 13 Wavelength Configuration 30 s 80 km 1 4666 2500 ns 1550 nm Ave Time Range IOR Pulsewidth Wavelength 8Km D...

Страница 23: ...tion use and to highlight VFL according to different demand press Enter to select CW 1Hz or off Press to exit When VFL is on icon will be displayed under B A icon which is in the right menu bar as in...

Страница 24: ...t Figure 3 17 IOR Configuration Use and to adjust the position of highlights use and to change the digits After setting press Enter to confirm Ave Time Range IOR 8Km Div 3 50 dB Div trace1 trc 15 20 1...

Страница 25: ...ion threshold press Enter to enter as shown in Figure 3 19 Press to exit Figure 3 19 Non Reflection Threshold Configuration 30 s 80 km 1 4666 2500 ns 1550 nm Ave Time Range IOR Pulsewidth Wavelength 8...

Страница 26: ...r to enter as shown in Figure 3 20 Press to exit Figure 3 20 Reflection Threshold Configuration Use and to adjust the position of highlights use and to change the digits After setting press Enter to c...

Страница 27: ...elete saved traces Under parameter configuration use and to highlight Delete file press Enter to enter as shown in Figure 3 22 Press to exit Figure 3 22 Delete File 30 s 80 km 1 4666 2500 ns 1550 nm A...

Страница 28: ...hin 5 minutes of idleness Under parameter configuration use and to highlight Auto off press Enter to switch as shown in Figure 3 24 Press to exit Figure 3 24 Auto off Configuration 30 s 80 km 1 4666 2...

Страница 29: ...of LCD Display Use and to adjust contrast and press Enter to confirm 1 4666 1550 nm Ave Time Range IOR Wavelength 8Km Div 3 50 dB Div trace1 trc 15 20 B A 2500 ns I O R 1 4666 N r e f l T h r e 0 20 d...

Страница 30: ...o enter as shown in Figure 3 28 Press to exit Figure 3 28 Load Default Use and to highlight yes or no press Enter to confirm B A 1 4666 1550 nm Ave Time Range IOR Wavelength 8Km Div 3 50 dB Div trace1...

Страница 31: ...L a n g E n g l i s h L C D C o n t r a s t L o a d D e f a u l t H e l p C o l o r M o d e C o l o r 2 Quick reference P a g e U p P a g e D o w n Q u i t 1 Connect the fiber and palmOTDR 2 Press or...

Страница 32: ...ly recharged the indicator will turn off When the instrument is power on and powered through AC DC adapter the inside batteries are automatically recharged The meanings of signals are as follows The b...

Страница 33: ...1 Power on Interface OTDR XXXX Model Version X X Software Version Three seconds after power on the interface will be automatically directed to quick reference Figure 4 2 Quick Reference 1 Connect fibe...

Страница 34: ...recise test trace even permanent damage for the OTDR 4 2 1 Trace Measurement Connect Optical Fiber Connect optic fiber to OTDR optic output directly no tools needed Clean connectors For details please...

Страница 35: ...lease refer to 3 4 3 2 Parameter Configuration on OTDR Menu Bar Set range to AUTO Measure press to start measurement and the interface is as in Figure 4 3 a b Figure 4 3 a Measuring Figure 4 3 b Measu...

Страница 36: ...e optimal measurement results Change range Refer to 3 4 3 2 2 range configuration to select adequate range Measure Press to start measurement The process is the same with Auto measurement 4 2 5 Trace...

Страница 37: ...s list upwards and downwards by the combining hot key Shift and Shift Enter in the keyboard 4 3 3 Review Marker A B Information 4 3 3 1 Switching between Marker A B Under GUI of Figure 4 4 use and to...

Страница 38: ...and to mover marker to event point to be observed For details please refer to 6 3 3 1 switching between Marker A B 4 7 Zoom out Trace Vertically This function is designed to zoom out trace vertically...

Страница 39: ...e will not exceed 8 characters of alphabet or Arabic numerals Save file use and to highlight OK press Enter to save Cancel saving file use and to highlight cancel press Enter to cancel the operation o...

Страница 40: ...er with which traces can be further processed on PC Install the software and run Power off OTDR Connect OTDR to PC through RS232 or USB interface cable Power on OTDR and upload data with the software...

Страница 41: ...is operation cannot be applied under GUI of parameter configuration save trace browse saved traces and measuring in progress 4 12 Alter Measurement in Realtime Testing To alter measurement in realtime...

Страница 42: ...ean periodically Effects of Cleaning Interfaces and Connectors The diameter of optic core is 9um and diameter of dust and other particulates ranges from 1 100 to 1 1 10 um Comparatively speaking the s...

Страница 43: ...r cleaning optic interfaces Isopropyl alcohol Cotton ball Paper tissue Cleaning brush Condensed air Preferred Procedure for Cleaning Interfaces and Connectors As in Figure 5 2 Preferred Procedure is a...

Страница 44: ...omer Service Center of the Provider to ensure proper initiation of your warranty term and scope of your warranty Returning Instruments To return instrument for reasons of yearly calibration or other p...

Страница 45: ...www PrecisionRatedOptics com 888 545 1254 45 OCC CWDM 301 18...

Страница 46: ...on Rated Optics Inc Corporate Office Billing Processing PO Box 877 Trexlertown PA 18087 Precision Rated Optics Inc Product Distribution Center Manufacturing Testing 9999 Hamilton Blvd Breinigsville PA...