SPECIFICATIONS
Rated Input Flow
6 GPM
Maximum Pressure 3,000 PSI
Internal Leakage
5 cu. in./min. @ 3,000 PSI
Filtration
Requirement
10 Micron minimum
Temperature Range -30°C to 120°C
(-22°F to 250°F)
Power Consumption 20W (1.7 A)
Port Size
8 ORB
INTRODUCTION
Applying power to the control valve extends a
hydraulic cylinder that alters the hydraulic oil
flow and reverses the direction of the circuit’s
hydraulic motor.
SAFETY
WARNING! Read and understand all
instructions before using this device. The
operator must follow basic precautions to
reduce the risk of personal injury and/or
damage to the equipment.
Keep this manual for safety warnings,
precautions, operating or inspection and
maintenance instructions.
1.
Use the correct device for the job. This
device was designed for a specific function.
Do not modify or alter this device or use it
for an unintended purpose.
2. Operate in a safe work environment.
Keep your work area clean, well-lit and free
of distractions.
3. Do not operate any device when tired
or under the influence of drugs, alcohol
or medications.
4. Always wear impact safety goggles that
provide front and side protection for the eyes.
Eye protection equipment should comply
with CSA Z94.3-07 or ANSI Z87.1 standards
based on the type of work performed.
5. Wear protective clothing designed for the
work environment and device.
6. Consult the safety precautions for your
hydraulic system when installing and
operating this valve.
UNPACKING
WARNING! Do not operate the device if any
part is missing. Replace the missing part before
operating. Failure to do so could result in a
malfunction and personal injury.
Remove the parts and accessories from the
packaging and inspect for damage. Make sure
that all items in the parts list are included.
Contents:
Control Valve
ASSEMBLY
1.
Connect positive wire (+) to
terminal 1.
2. Connect negative wire (-) to
terminal 2.
OPERATION
The valve does not have a neutral position. The
valve and its components are always under
pressure and the motor will always be in motion.
The hydraulic oil flows from Port 3 to Port 2,
through the hydraulic circuit and back out Port 4
to Port 1.
Applying power to the valve extends the
cylinder and the hydraulic
oil will flow from Port 3 to
Port 4, through the
hydraulic system and out
Port 2 to Port 1. This
reverses the oil flow in the
hydraulic circuit.
12V DC 4-WAY, 2-POSITION DIRECTIONAL CONTROL VALVE