pro.point 8688822 Скачать руководство пользователя страница 1

V1.0 

 

8688822 

Please read and understand all instructions before use. Retain this manual for future reference. 

SPECIFICATIONS 

Rated Input Flow 

10 GPM 

Maximum Pressure 

3,000 PSI 

Internal Leakage 

5 cu. in./min. @ 3,000 

PSI 

Filtration 

Requirement 

10 Micron minimum 

Temperature Range 

-30°C to 120°C  
(-22°F to 250°F) 

Power Consumption 

20W (1.7 A) 

Port Size 

8 ORB 

INTRODUCTION 

This valve is used to turn the hydraulic oil flow 

OFF or ON within the hydraulic system. The 

valve is closed and both ports are blocked 

when there is no power to the coil. The valve is 

open and allows flow in either direction when 

the coil is powered. 

SAFETY 

WARNING! Read and understand all 

instructions before using this device. The 

operator must follow basic precautions to 

reduce the risk of personal injury and/or 

damage to the equipment. 

Keep this manual for safety warnings, 

precautions, operating or inspection and 

maintenance instructions.  
1. 

Use the correct device for the job. This 

device was designed for a specific function. 

Do not modify or alter this device or use it 

for an unintended purpose. 

2.  Operate in a safe work environment. Keep 

your work area clean, well-lit and free of 

distractions. 

3.  Do not operate any device when tired or 

under the influence of drugs, alcohol or 

medications. 

4.  Always wear impact safety goggles that 

provide front and side protection for the eyes. 

Eye protection equipment should comply 

with CSA Z94.3-07 or ANSI Z87.1 standards 

based on the type of work performed. 

5.  Wear protective clothing designed for the 

work environment and device.  

 
 
 
 
 
 

UNPACKING 

WARNING! Do not operate the device if any 

part is missing. Replace the missing part before 

operating. Failure to do so could result in a 

malfunction and personal injury. 

Remove the parts and accessories from the 

packaging and inspect for damage. Make sure 

that all items in the parts list are included. 
Contents:

  

• 

Solenoid Valve 

ASSEMBLY & 

INSTALLATION 

WIRING 

1. 

Connect positive wire (+) 

to terminal 1. 

2.  Connect negative wire (-) 

to terminal 2. 

 

OPERATION 

Apply power to the 

solenoid to open the valve 

and allow hydraulic oil to 

flow. Stop supplying power 

to the valve to cut off the 

flow of oil. 

12V DC 2-WAY, 2-POSITION  

NORMALLY CLOSED DIRECTIONAL CONTROL VALVE 

Отзывы: