5.
Page 5-1
Orion
Machine Manual
Revision 3.1
Sentry HP/ LP Flex Stretchwrapper
21 May 2020
Maintenance
Maintenance
Maintenance
All general information about machine maintenance is based on normal machine working
conditions: indoor, moderate dust and low moisture environment, and maximum rotation
of 12 RPM. They should be regarded as guidelines, reviewed and corrected according to
requirements of actual use and conditions.
Motor Maintenance
The drive motors require little maintenance. Simply blow out debris with compressed air
on a regular basis.
Reducer Oil Change
All external cap screws and plugs on the reducing transmission should be checked for
tightness after the first week. It is recommended to change the oil every six months or at
least 1800 hours of operation, whichever comes first. When adding or changing oil, the
transmission should never be filled above the oil level mark indicated, because leakage
and overheating may occur. Below is the list of the type of lubricant that should be used.
List of recommended reducer oils:
Note:
For most applications, Mobil One Synthetic 75/90 gear lube is a pre-
ferred lubricant.
Table 5-1. Recommended Reducer Lubricants
MANUFACTURER
LUBRICANT
American Oil Co.
American Cyl Oil no: 196-L
Cities Service Oil Co.
Citgo Cyl Oil 100-5
Gulf Oil Corp.
Gulf Senate 155
Mobil Oil Corp.
Mobil 600 W Suer-r Cyl. Oil
Philips Oil Corp.
Andes S 180
Texaco Inc.
624 + 650T Cyl.Oil
Shell Oil Co.
Velvata Oil J82
Union Oil of Cal.
Red Line Worm Gear Lube 140
Содержание ORION Sentry HP
Страница 1: ...Revision Date May 21 2020 Revision 3 1 Sentry HP LP STRETCHWRAPPER MANUAL...
Страница 30: ...Machine Manual Orion Sentry HP LP Flex Stretchwrapper Revision 3 1 System Description 21 May 2020 Page 2 4...
Страница 88: ...Machine Manual Orion Sentry HP LP Flex Stretchwrapper Revision 3 1 Troubleshooting Contents 21 May 2020 Page II...
Страница 92: ...Machine Manual Orion Sentry HP LP Flex Stretchwrapper Revision 3 1 Maintenance Contents 21 May 2020 Page II...