background image

1

PS-3710A Series

Installation Guide

Package Contents

(1) PS-A Unit (1)

(2) English and Japanese Installation Guides 

(one of each) <This Guide>

(3) Warning/Caution Information (1)

(4) Installation Gasket (1) (attached to the 

PS-A unit)

(5) Installation Fasteners (Set of 4 x 2) 

(6) USB Cable Clamp (2 ports) (2)

(7) Power Plug (1)

(8) Power Switch cover (cover:1, secrew:1)

(AC type Only)

• Be careful when installing the PS-A not 

to damage the built-in HDD.

This unit has been carefully packed, with 
special attention to quality. However, should 
you find anything damaged or missing, 
please contact your local PS-A distributor 
immediately.

When you order a PS-A unit built to your 
specifications, that PS-A package should 
include each optional item's Installation 
Guide. Please use that guide to check the 
contents of each optional item's package.

About the Manual

For detailed information on PS-A series, refer 
to the following manuals.

• PS-3710A/PS-3711A Series Hardware 

Manual

• PS-3710A/PS-3711A Series Refer-

ence Manual

• API Reference Manual

Manual can be downloaded from Pro-face 
Home Page.

URL
http://www.pro-face.com/otasuke/

• The drivers and utilities for PS-A can be 

downloaded from Pro-face Home Page.

Caution

Be sure to read the “Warning/Caution 
Information” on the attached sheet before 
using the product.

AC type

(5.08mm pitch)

DC type

(7.62mm pitch)

Содержание PS3710A-T42

Страница 1: ...ntact your local PS A distributor immediately When you order a PS A unit built to your specifications that PS A package should include each optional item s Installation Guide Please use that guide to check the contents of each optional item s package About the Manual For detailed information on PS A series refer to the following manuals PS 3710A PS 3711A Series Hardware Manual PS 3710A PS 3711A Se...

Страница 2: ...N T R X V W O 1 Bottom Z P S Q U Y 2 PS3710A T42 N X W 1 S U Y 2 T R V O Z PQ PS3710A T42 24V LED PS A Status Green lit Normal Operation power is on Green blinking Soft OFF state Orange lit System Monitor Error Touch Panel Self Test Error Orange Red blinking Backlight burnout is detected Not lit Power is OFF LED PS A Status Green lit Currently using IDE I F ...

Страница 3: ... interface uses an RJ 45 type modular jack connector 8 pins P Ethernet Interface LAN2 10BASE T 100BASE TX 1000BASE T Auto Changeover This interface uses an RJ 45 type modular jack connector 8 pins Q Expansion Unit Interface 1 port Used to attach the PCI Unit R Serial Interface COM1 D SUB 9 pin plug type RS 232C RI 5V Changeover S Serial Interface COM2 D SUB 9 pin plug type RS 232C RI 5V Changeover...

Страница 4: ...be sure that power is turned OFF PS3710A T42 PS3710A T42 24V Power Supply Input Voltage AC100 240V DC24V Rated Voltage AC85 to 265V DC19 2 to 28 8V Rated Frequency 50 60Hz Allowable Voltage Drop 1 cycle or less Voltage drop interval must be 1s or more 5ms or less Power Consumption 150VA or less 110W or less Voltage Endurance AC1 500V 20mA for 1minute between charging and FG terminals AC1 000V 20mA...

Страница 5: ...llowing data In order to extend the lifetime of the hard disk Pro face recommends you set the Win dows 2000 or XP classic Control panel Power Options Power Options Proper ties Power Schemes Turn off hard disks selection to turn the hard disk off when the unit is not being operated A setting of 5 minutes is recommended Switches The following switch settings corresponding to Serial Interfaces and so...

Страница 6: ...ched when the SW is ON It is considered to be touched when the SW is OFF 2 Changes PIO DMA of CF Card PIO DMA PIO ON 3 Changes PIO DMA of CF Card PIO DMA PIO ON 4 Sets up an enabled disabled state for the port execution control function of hardware reset switch Disabled Enabled OFF The hardware reset switch is unavailable when the SW is ON But it is available to enter switch from the Soft OFF 2 st...

Страница 7: ...utput mode TX data output is controlled via the RTS signal TX data output is NOT controlled via the RTS signal normally output OFF ON OFF ON OFF 2 5 Switches the TX termination resistance ON OFF Inserts termination resistance of 220W between TXA and TXB No termination OFF ON ON OFF 3 6 Switches the RX termination resistance ON OFF Inserts termination resistance of 220W between RXA and RXB No termi...

Страница 8: ...cket 4 40 UNC Pin RS 232C Signal Name Description 1 CD Carrier Detect 2 RD RXD Receive Data 3 SD TXD Send Data 4 ER DTR Data Terminal Ready 5 GND Signal Ground 6 DR DSR Data Set Ready 7 RS RTS Request to Send 8 CS CTS Clear to Send 9 CI RI 5V 1 1 To change the RI 5V setting of 9 pin open the PS A unit s rear cover and set slide switch to the desired position Please refer to Switches for details Ca...

Страница 9: ...he circuit diagram refer to PS 3710A PS 3711A Series Reference Manual Pin RS 485 Signal Name Description 1 DATA Send Receive Data 2 DATA Send Receive Data 3 NC No Connection 4 NC No Connection 5 GND Signal Ground 6 NC No Connection 7 NC No Connection 8 NC No Connection 9 NC No Connection FG FG Frame Ground Common with SG Interfit Bracket 4 40 UNC Pin Signal Name Description 1 GND Ground 2 5V Outpu...

Страница 10: ...ing temperature 2 PS A Installation 1 Create a Panel Cut following the dimen sions in the table below 2 Confirm that the installation gasket is attached to the PS A unit and then place the PS A unit into the Panel from the front It is strongly recommended that you use the installation gasket since it absorbs vibration in addition to repel ling water For the procedure for replacing the installation...

Страница 11: ...Holes VESA 75mm Attach the four 4 M4 attachment screws Screw length 6mm 0 24 in or less The torque required for these screws is 0 7 to 0 8 N m 4 Removal Attachment the Rear Cover Use a screwdriver to loosen or tighten the screws Be sure not to tighten screws too tightly since it may damage the unit Be careful when removing or inserting any screws that they do not fall inside the PS A Unscrew the f...

Страница 12: ... Power Cord 1 Confirm that the power is not supplied to the PS A unit 2 Push the Opening button with a small and flat screw driver to open the desired pin hole 3 Insert each pin terminal into its each hole Release the Opening button to clamp the pin in place 4 After inserting all three pins insert the Power Plug into the Power Connector at PS A Fix the plug with two 2 slot screws Confirm that all ...

Страница 13: ...surge absorber that has a maximum circuit voltage greater than that of the peak voltage of the power supply 2 Grounding Cautions Be sure to create an exclusive ground for the Power Cord s FG terminal Use a grounding resistance of 100Ω a wire of 2mm2 or thicker or your country s applica ble standard The SG signal ground and FG frame ground terminals are connected internally in the PS A unit When co...

Страница 14: ...cable clamp 2 As shown insert the USB Cable Clamp s band through the Bridge Pass the USB cables through the Cable Clamp s band and securely tighten the clamp band around the cables Be sure the clamp is securely holding the USB cable s plug and collar Be sure the clamp is positioned as shown below with the clamp pointing upwards not to the side This is to keep the clamp from interfering with nearby...

Страница 15: ...s I Division 2 WARNING Explosion hazard do not disconnect equipment while the circuit is live or unless the area is known to be free of ignitable concentra tions WARNING Explosion hazard when using the PS A with the AC type power supply be sure to attach the Power Switch Cover Control Drawing of USB I F on PS A s Front Module The information below concerns the use of the USB I F located on the PS ...

Страница 16: ...i Suminoe ku Osaka 559 0031 JAPAN TEL 81 0 6 6613 3116 FAX 81 0 6 6613 5888 http www pro face com Copyright 2009 Digital Electronics Corporation All rights reserved PFX106519K PS3710A MT23E BTH 2012 3 JM D Inquiry Do you have any questions about difficulties with this product Please access our site anytime that you need help with a solution http www pro face com otasuke Please be aware that Digita...

Отзывы: