background image

3

„

LCD Panel Usage Precautions

The LCD panel’s liquid contains an irritant. If the panel is damaged and any of this liquid 
contacts your skin, immediately rinse the area with running water for at least 15 minutes. If the 
liquid gets in your eyes, immediately rinse your eyes with running water for at least 15 minutes 
and consult a doctor.

The PS-G unit’s LCD screen may show unevenness in the brightness of certain images or at some 
contrast settings. This is an LCD characteristic and not a product defect.

The PS-G unit’s LCD screen pixels may contain minute black and white-colored spots. This is an 
LCD characteristic and not a product defect.

The color displayed on the PS-G unit’s LCD screen may appear different when seen from outside 
the specified viewing angle. This is an LCD characteristic and not a product defect.

When the same image is displayed on the PS-G unit’s screen for a long period, an afterimage may 
appear when the image is changed. If this happens, turn off the PS-G, wait 10 seconds and then 
restart the unit. This is an LCD characteristic and not a product defect.

To prevent an afterimage:
* Set the PS-G unit’s display OFF feature when you plan to display the same screen image for a 

long period of time.

* Change the screen image periodically and try to not display the same image for a long period of 

time.

The term “PS-3600G” Series refers to the following PS-G model numbers:

PS3600G-T41 is a UL/c-UL recognized component (UL File No. 171486).

This product conforms to the following standards:

(A) UL60950-1

Information Technology Equipment-Safety-Part1

(B) CAN/CSA-C22.2 No.60950-1 (c-UL recognition)

Information Technology Equipment-Safety-Part1

PS-3600G Series Model Names

Series

Model

Description

Power Input Type

PS-3600G

PS3600G-T41

Windows

CE 5.0 (Japanese/ 

English version) is preinstalled 

as the operating system. 

Input voltage AC100/240V.

AC type

PS3600G-T41-24V

Windows

CE 5.0 (Japanese/ 

English version) is preinstalled 

as the operating system. 

Input voltage DC24V.

DC type

UL/c-UL Approval

Product Model No. UL Registration Model No.

PS3600G-T41

3384001-11

Содержание PS-3600G Series

Страница 1: ...PS 3600G Series Installation Guide...

Страница 2: ...ains cars and ships disaster and crime prevention devices various types of safety equipment non life support related medical devices and other similar equipment After the PS G unit s backlight burns o...

Страница 3: ...do not restrict or block the PS G unit s rear face ventilation slots Do not operate the PS G in areas where large sudden temperature changes can occur These changes can cause condensation to form ins...

Страница 4: ...image is changed If this happens turn off the PS G wait 10 seconds and then restart the unit This is an LCD characteristic and not a product defect To prevent an afterimage Set the PS G unit s displa...

Страница 5: ...ll it in a vertical panel Also it s recommended that the PS G should be mounted at least 100 mm away from any other adjacent structures or machine parts The temperature must be checked on the final pr...

Страница 6: ...s installation of the Adobe Corporation s Adobe Reader Adobe Reader 6 0 Installation To install the Adobe Reader software follow the steps given below 1 This software in the form of a self extracting...

Страница 7: ...r Input Terminal Block H Backup Battery Cover I Power Plug Connector A B C D E F H G D E F H I Back PS3600G T41 Back PS3600G T41 24V Front Common to PS3600G T41 and PS3600G T41 24V LED PS G Status Gre...

Страница 8: ...erface COM2 N Serial Interface COM1 O Ethernet Interface LAN P Speaker output interface Q CF Card Cover J K L Left Side Common to PS3600G T41 and PS3600G T41 24V Bottom PS3600G T41 24V Bottom PS3600G...

Страница 9: ...e Drop 1cycle max 10ms max Power Consumption 72VA max 32W max In Rush Current 60A max Excluding the input surge current 0 2 ms max to the built in noise filter 30A max Voltage Endurance AC1500V 20mA f...

Страница 10: ...original level of the protection cannot be guaranteed To maintain the original protection level be sure to replace the installation gasket regularly Physical Ambient Operating Temperature 0 C to 50 C...

Страница 11: ...hen you setup the system PS G Connector XM2C 0942 502LX OMRON Co Stacking Metal Fittings 4 40 inch screws Recommended cable Connector XM2D 0901 OMRON Co Recommended cable Cover XM2S 0913 OMRON Co Reco...

Страница 12: ...CS CTS Input Send Possible 9 VCC 5V 5 Output 0 25A 1 Shell FG Frame Ground Common with SG PS G Connector XM2C 1542 502L OMRON Co Stacking Metal Fittings M2 6 metric screw thread screws Recommended cab...

Страница 13: ...Expansion Unit Interface 1 Used to connect an S GMU bus compliant Expansion Unit Expansion Unit Interface 2 Used to connect a PCMCIA Card Adaptor Unit PSG PCM00 Speaker Output Interface Used to connec...

Страница 14: ...abinet or enclosure s internal temperature Be sure that heat from surrounding equipment does not cause the PS G to exceed its standard operating temperature When installing the PS G in a slanted panel...

Страница 15: ...then place the PS G unit into the Panel from the front 2 Installing the PS G unit in a Panel It is strongly recommended that you use the installation gasket since it absorbs vibration in addition to r...

Страница 16: ...is completely turned OFF via a breaker or similar unit The PS3600G T41 unit s are designed to use AC100 to 240 V input The PS3600G T41 24V is designed to use only DC24 V Supplying a power voltage othe...

Страница 17: ...und Terminal position the Ring Terminals and reattach the screws Check each wire to make sure the connections are correct 4 Reattach the Terminal Strip s clear plastic cover 1 Wiring for the PS3600G T...

Страница 18: ...G T41 24V unit DC24V Power Cord Diameter 0 2 to 2 5mm2 0 0001 to 0 0097inch2 24 to 12 AWG Conductor Type Simple or Twisted Wire 1 Conductor Length 24V 0V FG Grounding Terminal connected to the PS G Be...

Страница 19: ...put signal lines To avoid excess noise make the power cord as short as possible If the supplied voltage exceeds the PS G unit s range connect a constant voltage transformer For between the line and gr...

Страница 20: ...than 2mm2 0 0062inch2 Create the connection point as close to the PS G unit as possible and make the wire as short as possible When using a long grounding wire replace the thin wire with a thicker wi...

Страница 21: ...amp band around the cables Removal To remove the clamp from the USB cables push down on the clamp strap s clip to release it while pulling up on the clamp Peripheral Devices Installation 1 USB Cable C...

Страница 22: ...main unit Hook the upper pick of the USB holder to the attachment hole of the main unit and then insert the lower pick as shown below to fix the USB holder 2 Insert the USB cable into the USB Host Int...

Страница 23: ...attery refer to PS 3600G Series User Manual The Lithium Battery CR2032 is made by Hitachi Maxell Ltd There is a danger of explosion if the PS G unit s backup battery is incorrectly replaced This batte...