Chapter 6 Initializing the ST
6-13
6.4.2
Communication Setup
RECEIVE TIMEOUT (1-127)
PLC sets the value used for the data reception timeout (PLC-ST).
If the cable is not connected, data communication will Timeout in one second, regardless of this setting's
value. The default is "10" seconds.
RETRY COUNT (0-255)
Designates how many times the ST tries to send data to the PLC when a PLC communication error occurrs.
An Error Message will appear on the ST after the ST tries to send data to the PLC the number of times set by
this option. The default is "2".
6.4.3
Set Up Touch Panel
Touch operation and Force Reset setup, and Display Device adjustments are made here. There may be dif-
frences on these settings depending of the ST type.
TOUCH OPERATION MODE
Designates either One Point, Two Point or No Slide. When No Slide is selected, dragging one's finger across
the touch screen will elicit no screen response, and only individually selected points will register.
•
If you transfer screens when a PLC communication error has occurred and the error is not yet
cleared, and the RECEIVE TIMEOUT value is set to 30 seconds or more, an error message may
appear on your personal computer.
Содержание Pro-face ST Series
Страница 1: ...User Manual ST Series...
Страница 13: ...12 Memo...
Страница 18: ...1 1 1 Introduction 1 1 Prior to Operating the ST 1 2 System Design 1 3 Accessories...
Страница 54: ...4 1 4 Data Transfer 4 1 Serial Data Transfer 4 2 Ethernet Data Transfer...
Страница 61: ...ST Series User s Manual 4 8 Memo...
Страница 62: ...5 1 5 OFFLINE Mode 5 1 Entering OFFLINE Mode 5 2 OFFLINE Mode Main Menu 5 3 Initialization 5 4 Self Diagnosis...
Страница 123: ...ST Series User s Manual 7 24 Memo...
Страница 124: ...8 1 8 Maintenance 8 1 Regular Cleaning 8 2 Periodic Check Points 8 3 Changing the Backlight...