Chapter 1 - Introduction
1-2
PL-DU6900/PL-DU7900 User Manual
You canconnect a touch panel using either a RS-422 or a USB cable.
The RS-422 and USB cables have limitations concerning the PL type, OS type and
number of DU units.
1.1.1 RS-422 and USB Connections
5
6
7
0
ON
ON
ON
1
OFF
ON
ON
2
ON
OFF
ON
3
OFF
OFF
ON
4
ON
ON
OFF
5
OFF
ON
OFF
6
ON
OFF
OFF
7
OFF
OFF
OFF
Station
Number
SW No.
Touch Panle Cable
PL Type
OS Type
Display Connection Type
RS-422 Cable
PL-B900 Series,
PL-B910 Series
Windows
®
95,
Windows NT
®
4.0
Single Display
Single Display
Dual Display
USB Cable
PL-B910 Series
Windows
®
98
Second Edition
• When a DU is connectied via a USB cable, be sure to wait 3 seconds
after turning the power OFF before turning it ON again.
• Be sure to use only the OS types shown here with each cable. If a
different type OS is used, the utility software (drivers, etc.) is not
supported.
Dip Switch Settings
Depending on the touch panel cable used, the DU unit's rear face dip switch settings
will change. These settings must also be set on the PL unit's side face dip switches.
RS-422 Cable Settings
PL Setings
SW No.
1
2
3
4
On or OFF
ON
OFF
ON
OFF
DU Settings
SW No.
1
2
3
4
5
6
7
8
On or OFF
ON
OFF
ON
OFF
OFF
OFF
OFF
ON
PL Setings
SW No.
1
2
3
4
On or OFF
ON
OFF
ON
OFF
DU Settings
SW No.
1
2
3
4
5
6
7
8
On or OFF
OFF
ON
OFF
ON
OFF
Station Number
USB Cable Settings
For Station Number settings, Dip SW No.s 0 to 7 can be used. The combination of
Dip SW No.s 5 to 7 determines the Station Number. The following list shows dip
switch combinations and each combination’s allocated station number.