background image

3

General Specifications

„

Electrical Specifications

„

Environmental Specifications

DC model

AC model

Power Supp

ly

Input Voltage

DC24V

AC100 to 240V

Rated Voltage

DC19.2 to 28.8V

AC85 to 265V

Allowable Voltage Drop

10ms (max.)

1 cycle or less 

 

(Voltage drop interval 
must be 1s or more.)

Power Consumption

45W (max.)

AC100V 0.90A or less
(TYP 0.48A)
AC240V 0.45A or less
(TYP 0.26A)

In-Rush Current

30A (max.)

60A (max.)

Voltage Endurance

AC1000V 20mA for 

 

1 minute (between 
charging and FG 
terminals)

AC1500V 20mA for 

 

1 minute (between 
charging and FG 
terminals)

Insulation Resistance

DC500V 10M

 (min.)  (between charging and FG 

terminals)

P

h

ysi

c

a

l

Surrounding Air 
Temperature

0 to +50

°

C

Storage 
Temperature

-20 to +60

°

C

Ambient Humidity

10 to 90% RH 

 

(Wet bulb temperature: 39°C max. - no condensation.)

Storage Humidity

10 to 90% RH 

 

(Wet bulb temperature: 39°C max. - no condensation.)

Dust

0.1mg/m

3

 and below (non-conductive levels)

Pollution Degree

For use in Pollution Degree 2 environment.

Содержание AST-3501T

Страница 1: ...carefully packed with special attention to quality However should you find anything damaged or missing please contact your local ST distributor immediately About the Manual For the detailed informati...

Страница 2: ...odel Power Input Terminal Block E CF Card Cover F Serial Interface COM1 Dsub 9 pin plug type RS232C is supported G Serial Interface COM2 Dsub 9 pin plug type RS422 RS485 1 is supported 1 RS485 is comp...

Страница 3: ...ush Current 30A max 60A max Voltage Endurance AC1000V 20mA for 1 minute between charging and FG terminals AC1500V 20mA for 1 minute between charging and FG terminals Insulation Resistance DC500V 10M m...

Страница 4: ...2 01 on COM1 COM1 Recommended Cable Connector XM2D 0901 made by OMRON Corp Recommended Jack Screw XM2Z 0073 made by OMRON Corp Recommended Cable Cover XM2S 0913 made by OMRON Corp Interfit Bracket 4 4...

Страница 5: ...inch screws are used Pin RS422 RS485 1 1 RS485 is compliant with ST 3500 series units with revision code B or later Revision page 12 Signal Name Meaning 1 RDA Receive Data A 2 RDB Receive Data B 3 SDA...

Страница 6: ...tallation 1 Create a Panel Cut following the dimen sions in the table below 2 Confirm that the installation gasket is attached to the ST unit and then place the ST unit into the Panel from the front I...

Страница 7: ...e the wire is grounded Not ground ing the ST unit will result in excessive noise Use your country s applicable standard for grounding Power Cord Specifications Insertion Slot Recess Hook the fastener...

Страница 8: ...ctor Plug Specifications The power connector plug is CA5 DCCNL 01 made by Pro face or GMVSTBW2 5 3 STF 7 62 made by Phoenix Contact When connecting the Power Cord use the following items when performi...

Страница 9: ...resistance be sure to twist the ends of the power cord wires before connecting them to the Power con nector Plug The ST unit s power supply cord should not be bundled with or kept close to main circui...

Страница 10: ...wire and place it in a duct 5 Input Output Signal Line Cautions All ST Input and Output signal lines must be separated from all operating circuit power cables If this is not possible use a shielded c...

Страница 11: ...enclosure The ST unit must be used indoors only Install and operate the ST with its front panel facing outwards If the ST is mounted so as to cool itself naturally be sure to install it in a vertical...

Страница 12: ...81 0 6 6613 5888 http www pro face com Copyright 2006 Digital Electronics Corporation All rights reserved 085891J AST3500 MT01E BTH 2007 7 SS F Inquiry Do you have any questions about difficulties wi...

Отзывы: