background image

5.4

Removal and Replacement Of Sub-Units

5.4.1

Cards

Single card type modules may be removed and replaced with the system
powered or unpowered using card ejectors.  When replacing cards, care should
be taken to push them fully home.  All cards will work on the 1336 extender
board.

5.4.2

PSUs

Module type 1124, a mains powered switch mode power supply, housed within
the frame pr5V for the switcher cards and control card.  It may be
supplied configured for 110 Vac or 220/240 Vac, selected by a link internal to
the PSU.

A 'power on' LED is housed on the power supply front panel in addition to a
socket at the rear which allows external monitoring of both power supply
modules.

Outputs of the 1124 power supply are via diodes, allowing the inclusion of a
second power supply within the frame to provide back up power.

5.4.3

Sub-Assemblies

Sub-assemblies are secured at the rear of the frame by screws and care should
be taken during removal and replacement to support the boards and not to
stress leads.  Remove cable connections from the motherboard by holding the
connector shell, not pulling the wires.

5.5

Installation Note

On this unit all 'destination' connectors must be wired to the controller
equipment, and all 'source' to the tributary equipment.  The pinouts of these
connectors are such that for direct point-to-point connection between the router
and other equipment a pin to pin cable may be used  (e.g. IDC ribbon).

6521

6521

Page 8

ISS 3 DEC 97

Содержание 64x64 HD Series

Страница 1: ...RIPTION 6 5 INSTALLATION 7 5 1 Mechanical 7 5 2 Earthing 7 5 3 Modules 7 5 4 Removal and Replacement Of Sub Units 8 5 5 Installation Note 8 6 CONNECTOR DETAILS 9 6 1 Mains 9 6 2 Switcher Source Connectors 1636 Module 9 6 3 Switcher Destination Connectors 1636 Module 9 6 4 Local Control Connector Pinouts on 1537 Termination Panel 10 6 5 PSU Output Monitor 1537 11 7 MAINTENANCE AND WARRANTY 11 7 1 G...

Страница 2: ...upply Module 1537 PSU Control Connector Assembly 1636 Input Output Connector Assembly 2161 16 x 16 HD RS422 Crosspoint Module 2414 HD Series Switcher Control Module H050 HD Series Local Control Card User Manual 6521 6521 Page 2 ISS 3 DEC 97 ...

Страница 3: ...ns powered 64 input 64 output RS422 switcher in a 6U rack frame 6521 ISS 3 DEC 97 Page 3 6521 SOURCES A INPUTS B OUTPUTS DESTINATIONS A OUTPUTS B INPUTS NEXT DESTINATION GROUP CROSSPOINT CARD x 4 49 64 33 48 17 32 1 16 FIG 1 ROUTER ARCHITECTURE 1 16 ...

Страница 4: ... wire serial RS422 RS485 or RS232 with CTS RTS DTR and DSR Standard protocol Pro Bel General 2 4 Power Requirement Fully equipped 64 x 64 110 220 240V ac 10 50 60Hz at 130 VA internal dual power supplies 2 5 Mechanical Frame 6U 19 rack frame Width 483mm Depth 400mm Height 267mm Weight 20kg including dual power supplies 2 6 Operating Temperature Range 0 C to 40 C Cooling Natural convection 2 7 Conn...

Страница 5: ...which is powered via dual redundant PSUs and software controlled via serial interface type RS422 or RS232 A number of additional plug in modules are fitted which together form the switcher these are 2161 Crosspoint Module 2414 Local Control Module 1124 Power Supply Module 6521 ISS 3 DEC 97 Page 5 6521 ...

Страница 6: ...rol source and destination address lines are bussed across the 2161 cards to the local control card The switching cards contain local on board latches which suits them to a control system using serial data distribution This technique reduces non serial control wiring to individual card handshakes which provide card presence and power rail status The remaining control signal bussing comprise serial...

Страница 7: ...e system earths wired in the frame are accessible on a three way terminal block mounted on the rear of the power supplies The three earths are Mains Earth wired to the earth pin of the mains input connector Signal Earth wired to the system 0V supply and then to the signal cable screens Chassis Earth wired to the metalwork of the frame and cable connector metalwork These three earths are left entir...

Страница 8: ...lows external monitoring of both power supply modules Outputs of the 1124 power supply are via diodes allowing the inclusion of a second power supply within the frame to provide back up power 5 4 3 Sub Assemblies Sub assemblies are secured at the rear of the frame by screws and care should be taken during removal and replacement to support the boards and not to stress leads Remove cable connection...

Страница 9: ... Tributary equipment 6 3 Switcher Destination Connectors 1636 Module 9 way D screwlock socket Wired as Tributary connect to Controller equipment Pin Function 1 Chassis 2 Rx 3 Tx 4 Tx Common 5 N C 6 Rx Common 7 Rx 8 Tx 9 Chassis Pin Function 1 Chassis 2 Tx 3 Rx 4 Rx Common 5 N C 6 Tx Common 7 Tx 8 Rx 9 Chassis 6521 ISS 3 DEC 97 Page 9 6521 ...

Страница 10: ... 2 RS232 Serial Control Cannon 25 way D screwlock socket Pin Function 1 Chassis 2 Tx 3 Rx 4 Rx Common 5 N C 6 Tx Common 7 Tx 8 Rx 9 Chassis Pin Function 1 Chassis 2 Rx 3 Tx 4 DTR 5 RTS 6 DSR 7 0V 8 N C 9 N C 10 N C 11 N C 12 N C 13 N C 14 N C 15 N C 16 N C 17 N C 18 N C 19 N C 20 CTS 21 N C 22 N C 23 N C 24 N C 25 N C 6521 6521 Page 10 ISS 3 DEC 97 ...

Страница 11: ...ufacturers warranty typically one year Software Products Software Products are warranted for a period of ninety days from the date of shipment During this period Pro Bel undertakes to rectify products proved not to conform to the published specification provided with the product when used in accordance with PC hardware and operating systems approved by Pro Bel Loans Within the warranty period the ...

Страница 12: ...tely and appropriately packed for example do not pack static sensitive product in common polythene 7 2 1 UK Customers UK customers should return modules for repair marked as follows Customer Support Pro Bel Limited Danehill Lower Earley Reading Berkshire RG6 4PB England Telephone 44 0 118 986 6123 7 2 2 US Customers US customers should return modules marked as follows Service Department Pro Bel Am...

Отзывы: