PI Ignored
The PI (Paper Instruction) signal is used to control vertical paper
motion.
•
Enable
(default). Causes the printer to interpret the eight data
lines as DVFU commands when the PI signal is true.
•
Disable
. Ignores the PI signal and treats the data as characters
or control codes.
Data Polarity
The Data Polarity parameter must be set to match the data polarity
of your host computer.
•
Standard
(default). Does not expect the host computer to invert
the data.
•
Inverted
. Expects the data received on the data lines from the
host computer to be inverted. Ones become zeros, and zeros
become ones.
Resp. Polarity
The Response Polarity parameter must be set to match the
response polarity of your host computer.
•
Standard
(default). Does not invert the response signal.
•
Inverted
. Inverts the response signal sent to the host
computer.
Latch Data On
Specifies whether the data is read on the leading, middle, or trailing
edge of the data strobe signal. The default is Middle.
Prime Signal
•
Disable
(default). The parallel port will not perform a warm start
(reboot) if the host asserts the prime signal.
•
Enable
. The parallel port will perform a warm start (reboot) if
the host asserts the prime signal.
Содержание P5005B
Страница 10: ...Table of Contents 10...
Страница 18: ...Chapter 1 Printer Overview 18...
Страница 62: ...Chapter 2 Set The Top Of Form 62...
Страница 88: ...Chapter 3 Operational Procedures 88...
Страница 296: ...Chapter 5 RS 232 And RS 422 Serial Interfaces 296...
Страница 336: ...Appendix C 336...
Страница 340: ...Appendix D Federal Communications Commission FCC Statement 340...
Страница 365: ......