4–4
Adjustment Procedures
Belt, Platen Open, Adjustment (Figure 4–2 )
1.
Prepare the printer for maintenance (page 4–2).
2.
Open the printer cover.
3.
Remove the platen open belt cover (1) by squeezing the top and bottom
to release the plastic tabs from the slots in the side plate.
4.
Loosen the motor mount screws (2).
5.
Close the forms thickness lever all the way.
CAUTION
Too much tension on the platen open belt can cause the platen gap to
change, which can lead to premature wear of the platen, damaged
hammer tips, and poor print quality.
6.
Using a force gauge, apply 10
±
1 pounds of tension to the platen open
motor shaft (3), pulling away from the large platen pulley.
7.
Reduce tension to 5
±
1 pounds and torque the motor mount screws (2)
to 11
±
2 inch–pounds.
8.
Check the platen gap (page 4–14). Loosen the belt and readjust the gap
if necessary.
9.
Snap the platen open belt cover (1) into the slots in the side plate.
10. Return the printer to normal operation (page 4–22).
Содержание P4280
Страница 1: ...P4280 Line Matrix Printer Maintenance Manual R ...
Страница 2: ......
Страница 3: ...P4280 Line Matrix Printer Maintenance Manual R P N 155064 001 Rev B ...
Страница 67: ...4 7 Adjustment Procedures CORRECT NEEDS ADJUSTMENT NEEDS ADJUSTMENT Figure 4 3 Hammer Phasing Adjustment ...
Страница 179: ...6 11 Optional Equipment Tie Wrap CT Power Cable P N 155029 001 Tie Wrap Figure 6 5 Installing the CT Power Cable ...
Страница 236: ...A 22 Configuring the Printer ...
Страница 246: ...C 2 Torque Table ...
Страница 257: ...D 11 Wire Data Cable No Part No Description W1 150551 001 Cable Assembly CCB Mech Dr PIN 1 PIN 1 ...
Страница 263: ...D 17 Wire Data Cable No Part No Description W7 150649 001 Cable Assembly AC Ground PIN 1 ...
Страница 296: ...8 Index Notes ...
Страница 297: ......