PAGE 2
076/2613400
Copyright © Prins Autogassystemen B.V. 2014
VW Tiguan 1.4 CAXA /
CAXC
2
General instructions
The installation of the system shall be done in accordance with the installation manual provided by Prins
Autogassystemen.
This manual is based on Dutch regulations, always install the system in accordance to the local regulations.
Always download the “general manual 1/2 “ from our website for basic instructions and diagrams.
Always disconnect the battery when installing the LPG system. Make sure the ignition key is outside the car.
Be aware of central door locking, radio / telephone memory code, alarm system.
Do not place the main fuse into the fuse holder before having completed the installation of the VSI system.
The VSI computer has to be activated by means of the diagnosis software.
In the unlikely event the VSI computer fails, it will automatically switch over to petrol.
Never disconnect the VSI computer connector, unless you have removed the main fuse.
When installing the VSI wiring harness, ensure that it does not run near any of the ignition components.
Solder and insulate all electrical connections.
The wires in the loom are provided with numbers and text. The text on the wire explains the
function of the wire. The wire harness is not model specific, therefore is it may be necessary to
adjust the length of the wires. Ensure maximum care is taken when connecting wiring.
Make professional joints using solder and shrink sleeve. Do not stretch the wiring harness.
No component of the LPG-system shall be located within 100 mm of the exhaust or similar heat source,
unless such components are adequately shielded against heat.
Remove any internal burrs, after having shortened the LPG pipe. (This guarantees the maximum flow
through the pipe without pollution.)
If holes have to be drilled (wear safety glasses) for installing brackets, etc., the drilled holes must always be
treated with an anti-corrosion agent, after the chips have been removed ( especially when mounting a
exterior filler into body work).
After having completed the installation, check the whole system for gas leakage; use a gas leak detection
device. Also check for leak of engine coolant, petrol and air.
Fitting and maintenance is only allowed by Prins Autogassystemen selected LPG engineers.
Failure to follow the instructions in this manual can result in a poor or non-working gas installation
or a dangerous situation.
For maintenance instructions and filter registration see owner manual.
Prins Autogassystemen is not responsible for any damages to people or objects as a result of changes to
Prins products.
Check our website regularly for diagrams, certificates, updates, info-bulletins and product information.
Please fill in the warranty card completely and return it within 8 days after installation.