Alkaline Batteries
SECTOR 7
LED SPOTLIGHT
TM
www.princetontec.com
Operating and Maintenance Instructions
Notice d’utilisation et d’entretien
Bedienungsanleitung
Operation
Fonctionnement
Battery Installation
Mise en place des piles
ENGLISH
3
2
1
* Princeton Tec calculates total burn time as the
time it takes for the light source to produce a
minimum of 0.25 lux at 2 meters. 0.25 lux is about
the equivalent of a full moon on a clear night.
Regulated burn time is less than overall burn time.
* Princeton Tec définit la durée totale d’éclairage
comme le temps nécessaire à la source lumineuse
pour produire un minimum de 0,25 lux à 2 mètres.
0,25 lux équivaut à peu près à la luminosité d’une
pleine lune dans un ciel nocturne dégagé. La durée
d’éclairage régulé est inférieure à la durée
d’éclairage globale.
1
Maxbright
LED
DISTANCE (Meters)
50
225
REGULATED
4 H
TOTAL
30 H
Momentary
Half Pull
Constant
Pull
Battery Installation - See Battery Installation
Diagram
Princeton Tec cares about the environment and
recommends recycling batteries. For more
information about battery recycling, please go
to: www.batteryrecycling.com.
Observe proper battery polarity when installing
the batteries. Improper installation of the
batteries will damage the light and void the
warranty.
WARNING:
• Never mix fresh and used batteries.
• Never mix different battery brands or
chemistry types
• Always remove drained batteries immediately.
• Remove batteries during long periods of
storage.
NOTE: Some battery formulations can emit
hydrogen gas. This gas can create an explosion
potential in sealed devices if not vented or
removed. The Sector
TM
7 is equipped with a
platinum catalyst that will remove this gas.
When replacing the batteries, visually inspect
the LED module for broken or missing catalyst.
If the catalyst appears to be damaged, (you may
notice gray particles in the battery compart-
ment), or the light has flooded, replace the
catalyst before using.
Switch Operation See Operation diagram
To turn the light on, unlock the on/off switch by
rotating the lock forward until it clicks into the
trigger mechanism. For momentary light, pull the
trigger back half way; release when light is no
longer needed. For constant on mode, pull the
trigger back all the way and release. Completely
actuate the trigger again to turn the spotlight off.
After use, rotate the lock back until it clicks into
place so the trigger mechanism will not move.
This will prevent the light from being turned on
accidentally.
O-Ring
Occasionally clean and lightly lubricate the
O-Ring and lens cap threads. Use only silicone
grease, never use aerosol spray lubricants.
WARNING:
• All plastic components are made of
high-impact resistant polycarbonate plastic.
Certain forms of aerosol sprays can cause
damage and void warranty.
• To avoid water leakage, do not over tighten
the lens cap.
Maintenance
As with any equipment, the Sector
TM
7 should be
rinsed with fresh water after any contact with
salt water. Move the switch and switch lock
back and forth a few times while rinsing with
water to prevent salt build-up.
Flooding
In the unlikely event your light leaks or is
flooded, immediately remove the batteries.
Flush all parts with fresh water and allow to dry.
Check for possible cause of leakage and correct
problem; return light for repair if necessary. Do
not reuse batteries that have been wet. Batteries
from a flooded light should be discarded.
Troubleshooting
If the Sector
TM
7 fails to light:
• Check the batteries for proper installation.
• Replace batteries if proper installation is
confirmed.
USA Lifetime - International 10 Year Warranty
WARRANTY – Princeton Tec warrants this product
to be free from defects in workmanship and
materials under normal use for as long as you own
this product. This warranty covers all of the
component parts of the product except batteries.
This warranty does not cover deterioration due to
normal wear or damage due to misuse, alteration,
negligence, accidents, or unauthorized repair.
Princeton Tec will repair or replace parts which are
defective in workmanship or materials.
Your authorized Princeton Tec Dealer and
Princeton Tec are the only facilities authorized to
repair the product. After (3) unsuccessful attempts
(within the warranty period) to repair the product,
you have the right to elect replacement of the
product or a refund of the purchase price less
allowance for use of the product. NO INCIDENTAL
OR CONSEQUENTIAL DAMAGES ARE
INCLUDED IN THIS WARRANTY. (Some states do
not allow the exclusion or limitation of incidental or
consequential damages, so the above limitations
or exclusions may not apply to you.) This warranty
gives you specific legal rights, and you may also
have other rights which vary from state to state.
Princeton Tec reserves the right to change product
specifications without notice.
Return Policy
IIf your light fails to operate, follow these simple steps:
1) Check batteries. Replace if necessary.
2) Contact Princeton Tec customer service at
800-257-9080 to request an RMA number in order to
send your light for repair or replacement. No
warranties will be accepted without an RMA number.
3) If the light continues to function improperly, return it
without batteries to: Princeton Tec, 5198 Rt. 130
Bordentown, NJ 08505. Postage due and freight
collect items will not be accepted.
Princeton Tec
PO Box 8057,
Trenton, NJ 08650
Phone: 609-298-9331
Fax: 609-298-9601
© 2014 Princeton Tec
LOCKED
POSITION
UNLOCKED
POSITION
Betrieb
Einlegen der Batterien
12
14
Princeton Tec berechnet die Gesamtbrenndauer
bezogen auf eine von der Stirnlampe erzeugte
minimale Beleuchtungsstärke von 0,25 Lux in 2 Meter
Abstand. 0,25 Lux entsprechen in etwa der Beleuch-
tungsstärke des Vollmonds in einer klaren Nacht.
*
Finished Fold Size = 2.4” x 3.855”
Front