22
PhotonMAX System Manual
Version 1.B
Checking the Equipment and Parts Inventory
Confirm that you have all of the equipment and parts required to set up the PhotonMAX
system. A complete system consists of:
•
Camera
•
Power Supply
(or a CoolCUBE coolant circulator for liquid-cooled versions)
•
Host Computer:
Can be purchased from Princeton Instruments or provided by user.
•
Computer Interface Components:
•
Data cable:
15 ft (5 meter) cable (6050-0545) is standard.
•
Proprietary PCI Card
•
I/O cable: (Optional)
2 ft ( .6 meter)
cable (6050-0546) with DB26 connector at
one end and five (5) BNCs at the other end.
•
PhotonMAX System User Manual
•
WinView/32 or WinSpec32 CD-ROM
(optional)
•
Software User Manual
System Requirements
Environmental Requirements
Storage temperature:
≤
55°C
Operating environment temperature: 5ºC to +30ºC; the environment temperature range
over which system specifications can be guaranteed is +18ºC to +23ºC
Relative humidity
≤
50%; non-condensing
Note:
For TE-cooled cameras, the cooling performance may degrade if the room
temperature is above +23°C.
Ventilation
Camera:
Allow at least two (2) inches (50 mm) clearance around the vented covers. The
air needs to be less than 25ºC (above this temperature the CCD temperature can
begin to degrade). Where the camera is inside an enclosure, the enclosure needs
to have unrestricted flow to an open environment. The camera vents its heat out
the vents near the nose. The air intake is near the rear of the camera.
Power
Camera:
The PhotonMAX camera receives its power from the supplied power supply
(or the liquid circulator unit), which in turn plugs into a source of AC power.
Power Supply:
The receptacle on the power supply should be compatible with the
line-voltage line cords in common use in the region to which the system is
shipped. If the power supply receptacle is incompatible, a compatible adapter
should be installed on the line cord, taking care to maintain the proper polarity to
protect the equipment and assure user safety. For the liquid-cooled version,
power to the camera is supplied via the CoolCUBE circulator unit.
Maximum Power Output:
96 W
Input:
100-240 VAC, 47-63 Hz, 3 A
Output:
12 VDC at 8 A maximum
Содержание PhotonMAX System
Страница 1: ...4411 0107 Version 1 B January 26 2006 4411 0107...
Страница 12: ...12 PhotonMAX System Manual Version 1 B This page intentionally left blank...
Страница 20: ...20 PhotonMAX System Manual Version 1 B This page intentionally left blank...
Страница 66: ...66 PhotonMAX System Manual Version 1 B This page intentionally left blank...
Страница 78: ...78 PhotonMAX System Manual Version 1 B This page intentionally left blank...
Страница 81: ...This page intentionally left blank...
Страница 82: ...82 PhotonMAX System Manual Version 1 B This page intentionally left blank...
Страница 87: ...87 Appendix B Outline Drawings Note Dimensions are in inches mm PhotonMAX Camera C mount Air Cooled...
Страница 88: ...88 PhotonMAX System Manual Version 1 B PhotonMAX Camera C mount Liquid Cooled...
Страница 89: ...Appendix B Outline Drawings 89 CoolCUBE Circulator...
Страница 90: ...90 PhotonMAX System Manual Version 1 B This page intentionally left blank...