70276001
37
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
48. STEAM COILS
Refer to Figure 10.
a. Shut off inlet and outlet valves and disconnect
flex hoses from steam coils
b. Remove screws holding cover to top of steam
heating unit and remove cover.
c. Remove air filters.
d. Remove screws holding steam coils to coil
frame.
e. Remove screws from damper.
f. Remove steam coils by lifting straight up and
out of tumbler.
NOTE: When removing or replacing steam coils, be
careful not to damage fins on steam coils.