4.2
Installing a Mounting bracket
Before installing the inverter, secure the shipped mounting bracket kit to a wall.
Step 1 : Move out the mounting bracket kit from the packing case.
Step 2 : Determine the positions for drilling holes (as shown in Figure 4.10) using the
mounting bracket kit.
Figure 4.10 Determine the positions for drilling holes (unit: mm)
Step 3 : Level the hole positions using a level, and mark the hole positions using a
marker (as shown in Figure 4.11).
Figure 4.11 Mark the hole positions using a marker
Step 4 : Drill holes using a hammer drill and install expansion bolts, as shown in Figure
4.12.
DANGER
Before drilling the hole on the wall, ensure no damage on the
electric wire and / or water pipe inside the wall.
PV-3000S-V/PV-3600S-V
PV-5000S-V/PV-5000S-HV
Level ruler