PrimeVOLT PV-3000S-V Скачать руководство пользователя страница 1

 

 

Your PV Inverter Professional

Prime

VOLT

 

SINGLE PHASE ON-GRID PV INVERTER

 

PV-3000S-V/PV-3600S-V/PV-5000S-V/PV-5000S-HV

 

2

 

 

Installation & Operation Manual 

 

 
Version 0.0  Nov. 2019 

Printed on Recycled Pap 

Содержание PV-3000S-V

Страница 1: ...1 Your PV Inverter Professional PrimeVOLT SINGLE PHASE ON GRID PV INVERTER PV 3000S V PV 3600S V PV 5000S V PV 5000S HV 2 Installation Operation Manual Version 0 0 Nov 2019 Printed on Recycled Pap...

Страница 2: ...2 4 Working Process 10 3 Storage 11 4 Installation 12 4 1 Determining the Installation Position 14 4 2 Installing a Mounting bracket kit 19 4 3 Installing the Inverter 20 5 Electrical Connections 21 5...

Страница 3: ...consulting your dealer For more product information please visit PrimeVOLT website or contact with our sales representatives Thanks you so much for your choosing the latest generation of grid tied PV...

Страница 4: ...t correctly followed could result in serious injury or death CAUTION Indicates a potentially hazardous situation which if not correctly followed could result in moderate or minor injury NOTICE Indicat...

Страница 5: ...ormation about safe operation Do not remove or damage the nameplate on the inverter s enclosure because it contains important product information Do not remove the anti dismantle label on the inverter...

Страница 6: ...he procedures of commissioning described in the user manual when commissioning the PV inverter Do not touch any other part s surface except the DC switch when the PV inverter is operating its partial...

Страница 7: ...mer before grounding the positive negative terminal of PV modules like Thin Film module for operation WARNING Do not connect PV modules in parallel to several PV inverters for operation 2 2 Network Ap...

Страница 8: ...ure 2 2 PV 3000S V PV 3600S V dimension unit mm PV 5000S V PV 5000S HV Figure 2 3 PV 5000S V PV 5000S HV dimension unit mm Outline PV 3000S V PV 3600S V PV 5000S V PV 5000S HV Figure 2 4 PV 3000S V PV...

Страница 9: ...PV 5000S HV rear view Overview of Connection Area DC Switch Communication interface DC PV Input connectors Vent valve AC Output connector External Protection Ground interface Figure 2 6 PV 3000S V PV...

Страница 10: ...feed to the Power grid EMI filter is used on both the DC and AC sides to reduce the electromagnetic interface Surge protection is supported on AC side Circuit Diagrams Figure 2 9 shows the circuit di...

Страница 11: ...g a fault or a shutdown command Shutdown The PV inverter switches from standby or operating mode to shutdown mode if detecting a fault or a shutdown command The inverter switches from shutdown mode to...

Страница 12: ...ving the inverter check that the packing materials are intact After unpacking check that the deliverables are complete intact and consistent with your order list Examine the PV inverter and its fittin...

Страница 13: ...verter Identify the PV Inverter After moving the PV inverter from packing box identify it by reading its nameplate labeled on the side of the inverter The nameplate contains important product informat...

Страница 14: ...r is protected to IP65 and can be installed indoors or outdoors PV 3000S V PV 3600S V PV 5000S V PV 5000S HV weight and dimension as shown in Table 4 1 The installation method and position must be app...

Страница 15: ...environment with awning unit mm Carrier Requirements The wall must be solid enough to bear the weight of the inverter Do not install the inverter on a wall made of gypsum boards or similar materials...

Страница 16: ...shown in Figure 4 5 if sufficient space is available and install them in triangle mode as shown in Figure 4 6 or in stacked mode as shown in Figure 4 7 if no sufficient space is available The installa...

Страница 17: ...17 Figure 4 6 Installation in triangle mode unit mm Figure 4 7 Installation in stacked mode unit mm...

Страница 18: ...e inverter upright or at a maximum back tilt of 15 degrees to facilitate heat dissipation Below are some correct wrong installation modes as shown in Figures 4 8 4 9 The correct installation mode Figu...

Страница 19: ...ure 4 10 Determine the positions for drilling holes unit mm Step 3 Level the hole positions using a level and mark the hole positions using a marker as shown in Figure 4 11 Figure 4 11 Mark the hole p...

Страница 20: ...t kit with the holes insert expansion bolts into the holes through the mounting bracket kit and tighten the expansion bolts to a torque of 2 2 5 N m using a torque wrench as shown in Figure 4 13 Figur...

Страница 21: ...Outdoor copper core cables with a cross sectional area of 4 mm2 or more are recommended OT terminal OT1 6 4 NOTE Good grounding for the inverter helps resist the impact of surge voltage and improve t...

Страница 22: ...as shown in Figure 5 3 Figure 5 3 Remove the ground screws Step 4 Secure the PGND cable done by step 1 2 using the ground screw and tighten the screw to a torque of 1 2 N m using a socket wrench as sh...

Страница 23: ...al sleeve in the intermediate L terminal of line wire N terminal of neutral wire into E terminal of Earth Wire tighten the screw The required torque is 0 8 N m After fixing the cables tighten the nut...

Страница 24: ...the safe range and that the DC SWITCH on the inverter is OFF Otherwise high voltage may result in electric shock When the inverter is grid tied it is not allowed to maintain DC input power cables such...

Страница 25: ...er model Number of Input Route PV 3000S V PV 3600S V PV 5000S HV Connected to route 1 PV 5000S V Connected to route 2 PV String DC input cable and connectors have been prepared Table 5 2 lists the rec...

Страница 26: ...he positive and negative connectors respectively and crimp them using a crimping tool as shown as Figure 5 11 Figure 5 11 Crimping a metal connector Step 3 Insert the crimped positive and negative pow...

Страница 27: ...ings using a multimeter The PV 3000S V PV 3600S V PV 5000S V not over 600VDC voltage PV 5000S HV not over 1000VDC voltage and ensure that the polarities of the DC input power cables are correct as sho...

Страница 28: ...RS485 interface by RS485 communication card and upload the inverter data to cloud monitoring system through external data logger For example PrimeVOLT s external data logger V1000 or V1000L Standard...

Страница 29: ...ure 5 19 Loosen the four locking nuts on TB1 Lock the metal cover on TB1 Tidy up these wires as follows wires from the T R1 and T R1 holes of TB1 come out through the bottom holes and these from the T...

Страница 30: ...side facing the left Then insert the shell into the guide slot according to the trend Figure 5 20 RS485 module connecting with DB9 port Step 5 Lock the waterproof connector on the RS485 cover and tig...

Страница 31: ...Download the APP Android please go to the Google Play Store to download the PrimeVOLT APP iOS please go to the Apple Store to download the PrimeVOLT APP Execute the PrimeVOLT APP Select the inverter S...

Страница 32: ...especially the screws used for electrical connections are tightened 3 The PV inverter is installed correctly and securely 4 Ground AC DC and communications cables are connected tightly correctly and...

Страница 33: ...inverter according to Table 7 1 NOTE When LED status lights display the inverter has entered grid connecting it means the inverter is operating well Any query during operating the PV inverter call yo...

Страница 34: ...Communication in normal Warning OFF No warning ON Refer error message table LCD display The display contents information include output power grid voltage current PV module voltage current energy of...

Страница 35: ...detection failed C7 Anti islanding detection failed FAN FAILS Fan not working properly F1 Bus voltage low F2 Bus voltage high F3 CPU communication abnormal F4 Mismatch of firmware version between CPUs...

Страница 36: ...eplace the relevant part monthly PV inverter Electrical Connections Check that AD DC and communications cables are securely connected Check that PGND cables are securely connected Check that cables ar...

Страница 37: ...ng term moist environment Check the insulation resistance against the ground for the PV strings If a short circuit has occurred rectify the fault Residual Current Abnormal The insulation resistance ag...

Страница 38: ...oid inverter damage and personal injury Warranty or liability will be void if damage caused by but not limited to the following Unauthorized opening of unit Installation faults such as improper enviro...

Страница 39: ...20 500 800 Max number of inputs 1 1 2 1 Output AC Rated output power W 3000 3600 5000 5000 Max apparent power VA 3300 3960 5500 5500 Max output current A 14 3 17 2 23 8 23 8 Max output over current pr...

Страница 40: ...6 3 4 EN 61000 3 11 EN 61000 3 12 EN 61000 6 3 EN 61000 3 11 EN 61000 3 12 EMC Immunity EN 61000 6 1 2 EN 61000 6 2 Protection Input DC switch Anti islanding protection Output short circuit protectio...

Отзывы: