9.5.2
Configure advanced settings
1. Click on the
Advanced
tab.
2. Maintain the options according to the
explanations in in the following table:.
Option
Explanation
Save device settings
All options marked with an asterisk in the
Device control
menu can be
saved in the EEPROM of the device.
These and other options for saving / loading configurations are descri-
bed in chapter 9.4.4 on page 53.
# Pixel in x/y *
This option enables setting the resolution of the CCD sensor:
X
Enter the number of pixels in the x-direction / y-direction in the input
field on the left / right.
Low power mode
This option is only relevant when performing a beam search (
Find beam
option, see chapter 9.5.1 on page 57). We recommend activating it
for low power laser beams (< 1 W).
If this option is enabled, the following initial values are selected during
beam search
• Filter level of the filter wheel: 0 (instead of 1 otherwise)
• Integration time: 10 ms (instead of 1 ms otherwise).
X
Set the check mark to enable the option.
Calibrated wavelength(s) in nm *
X
Select the calibrated wavelength in the drop-down list.
The values displayed correspond to the calibration points of the
measuring objective. The correct value should be selected before each
measurement to enable high measurement accuracy.
Used wavelength in nm *
Use one of the following options to set the used wavelength of the laser:
X
Enter a value in the input field.
X
Use the slider below the input field.
This parameter must be distinguished from the factory calibrated wave-
length of the measuring objective. The exact value should be entered,
because it is used for calculating the significant beam quality factor M².
The wavelength used should approximately match the calibrated wave-
length. To enable high measurement accuracy, a pre configured accep-
tance range must be observed. For example, if the calibration point
1 064 nm is selected, measurements can be taken in a range between
1 030 and 1 100 nm with high measurement accuracy.
Hence the value from the
Calibrated wavelength in nm
option is au-
tomatically adopted in the input field if a new selection was made there.
If this value is replaced by an impermissible high / low value, the imper-
missible value is automatically overwritten with the maximum / minimum
permissible value.
Magnification
This field displays the magnification of the measuring objective.
Focal length of focusing optics in mm *
X
Enter the focal length used by the focusing optics of the laser
system.
If several planes of a caustic have been measured, the caustic fit and the
entered focal length are used to calculate the raw beam diameter on the
focusing optics.
Tab. 9.4:
Options in the
Device control > Advanced
tab of the
Single planes
measuring mode
Содержание MicroSpotMonitor Plus HighBrilliance
Страница 2: ......
Страница 3: ...3 Revision 00 EN 02 2022 MSM HB 35 0 6 IMPORTANT READ CAREFULLY BEFORE USE KEEP FOR FUTURE USE...
Страница 7: ...7 Revision 00 EN 02 2022 MSM HB 35 0 6...
Страница 95: ...95 Revision 00 EN 02 2022 MSM HB 35 0 6 13 Declaration of conformity...
Страница 96: ...96 Revision 00 EN 02 2022 MSM HB 35 0 6...
Страница 98: ...98 Revision 00 EN 02 2022 MSM HB 35 0 6 15 Dimensions 15 1 Dimensions of the MSM HB10 A...
Страница 99: ...99 Revision 00 EN 02 2022 MSM HB 35 0 6 Dimensions of the MSM HB10 continued View A...
Страница 100: ...100 Revision 00 EN 02 2022 MSM HB 35 0 6 15 2 Dimensions of the MSM HB10 with fibre bridge A...
Страница 101: ...101 Revision 00 EN 02 2022 MSM HB 35 0 6 Dimensions of the MSM HB10 with fibre bridge continued B View A...
Страница 102: ...102 Revision 00 EN 02 2022 MSM HB 35 0 6 Dimensions of the MSM HB with fibre bridge continued View B...
Страница 103: ...103 Revision 00 EN 02 2022 MSM HB 35 0 6 15 3 Dimensions of the MSM HB20 at zmax C...
Страница 104: ...104 Revision 00 EN 02 2022 MSM HB 35 0 6 Dimensions of the MSM HB20 continued View C...
Страница 105: ...105 Revision 00 EN 02 2022 MSM HB 35 0 6 15 4 Dimensions of the MSM HB20 with fibre bridge at zmax D...
Страница 106: ...106 Revision 00 EN 02 2022 MSM HB 35 0 6 Dimensions of the MSM HB20 with fibre bridge continued View D...
Страница 116: ...116 Revision 00 EN 02 2022 MSM HB 35 0 6...