Installing/Removing the Rack Model
Hardware Installation
4.3.2
Installation in Classic Rack
A special conversion kit (S26361-F1331-L200 without cable arm or
S26361-F1331-L300 with cable arm) is needed for fitting in the Classic (19 inch
42/23 HU) rack:
–
one support system on the left and one on the right (mounted)
–
articulated cable guide
–
protective hose for fiber channel fiber optic cable
I
General information about rack installation can be found in the Technical
Manual for the Classic (19 inch) rack and in the leaflet that accompanies
the conversion kit.
Ê
Mark the position of the attachment points for the telescopic rails and for the
server (front panel) on the support uprights (four height units).
Ê
Place the spring nuts for fixing the adapters in the groove on the support
uprights at the marked fixing points.
Ê
Place the M5 spring nuts for securing the server in the groove on the front
faces of the front support uprights.
Ê
Adjust the position of the nuts in the groove until they engage at the correct
position.