248
Chapter 9 Operation and Maintenance
■
Server Management Tools Error Messages
The following error messages may appear while executing Server Management Tools. In such cases,
perform the corresponding corrective actions. If messages other than the following are displayed,
contact an office listed in the "Contact Information" of the "Start Guide".
Warning:DIMM Type Mismatch, has Log. The
DIMM has been Disabled!
Varying types of memory modules have been installed together.
Check the system event log and replace memory in the bank.
Warning:Memory Mirror Feature could not be
enabled.
Since the memory configuration is invalid, the memory
redundancy function is not available.
When using the memory redundancy function, check that two or
more even numbers of memory banks of the same size are
installed.
When not using the memory redundancy function, check that
[Memory Mirror] is set to [Disabled] in "8.2.11 Memory Status
Submenu" (
pg.222) on the [Server] menu of the BIOS Setup
Utility.
If the message still appears, the server blade must be replaced.
Contact an office listed in the "Contact Information" of the
"Start Guide".
Warning:DIMM Type mixed has Log. The DIMM has
been Disabled!
Varying types of memory modules have been installed together.
Check the system event log and replace memory in the bank.
table: Server Management Tools: List of Error Messages
Message
Description
Write protect error writing drive A.
Abort, Retry, Fail?
The inserted floppy disk is write-protected. Disable the
write-protect, and then press the [R] key.
Not ready writing drive A.
Abort, Retry, Fail?
The floppy disk is not inserted into the floppy disk drive.
Insert the proper floppy disk ("Server Management Tools"
floppy disk), and then press the [R] key.
ERROR:Fail to create data file.
The following are possible causes. Check the floppy disk
status.
• The floppy disk is write-protected. Disable the write-
protect and retry.
• The floppy disk is not inserted into the floppy disk drive.
Insert the proper floppy disk, and then retry.
• There is an error in the contents of the floppy disk. Create
the "Server Management Tools" floppy disk again. If this
occurred while recovering BIOS information, configure
the information using the BIOS Setup Utility. Then store
the BIOS information.
ERROR:Fail to write 1st CMOS data into data
file. nn
ERROR:Fail to write 2nd CMOS data into data
file. nn
ERROR:Fail to write ESCD data into the data
file. nn
ERROR:Fail to write SEEPROM data into the
data file. nn
ERROR:Fail to open data file.
The file for recovering the BIOS information does not exist
on this floppy disk. Insert the floppy disk on which the BIOS
information was stored, and then retry.
table: List of POST Error Messages
Message
Contents and troubleshooting
Содержание BX620 S3
Страница 30: ...30 Chapter 1 Overview ...
Страница 164: ...164 Chapter 5 Operations after OS Installation ...
Страница 172: ...172 Chapter 6 High Reliability Tools ...
Страница 238: ...238 Chapter 8 Hardware Configuration Utilities ...
Страница 276: ...276 Chapter 9 Operation and Maintenance ...
Страница 286: ...286 Numerics 2 5 inch storage bay 26 27 ...