Chapter 7 Installing Internal Options
7.2 Removing and Attaching the Top
Cover
This section explains how to remove and attach the top cover.
7.2.1 How to Remove the Top Cover
1
Turn off the server.
→
"3.3 Turning Off the Server" in "BX600 S2 Blade Server System Unit Hardware Guide"
2
Touch a metal part of the chassis to discharge static electricity.
3
Remove the target server blade from the chassis.
→
"4.2 Installing Server Blade" in "BX600 S2 Blade Server System Unit Hardware Guide"
4
While pressing the button, slide the top cover a little backward, and carefully
pull it up.
■
How to Attach the Top Cover
To attach the top cover, simply reverse the removal procedures.
Make sure that no tools or unnecessary components were left inside the server before attaching the
top cover back into place.
Before turning on the server, make sure that the top cover is attached.
• When installing or removing the top cover, make sure to remove the server
blade from the chassis. Failure to do so may cause electric shock.
For details on how to remove the server blade from the chassis, refer to
"BX600 S2 Blade Server System Unit Hardware Guide".
• Use tip preventive stabilizers when installing the rack. Pulling the server blade
out of the rack without installing stabilizers may cause the rack to tip over.