background image

 
 

 

ECO Valve

 

Uses: 

 

Back Pressure valve

 

 

Anti-Siphon valve

 

 

Pressure Sustaining valve

 

 

Pressure Relief valve

 

 

 
 
 
 
 

Instruction Manual

 

1” (High Flow), 1 ¼”, 1 ½” and 2” (“C” Series) 

 

ECO-110, ECO-125, ECO-150 and ECO-200

 

06/2017 

Rev. 4 

 

 
 
 
 
 

Please note:

 

This instruction manual provides detailed information and instructions that must be read, understood and 
followed to ensure that the equipment is installed, operated and serviced in an appropriate manner.

 

Failure to do so before using may result in hazardous consequences and/or improper operation.

 

 

 

 
 

 

 
 

 

 
 

 

 
 

 

 
 

 
 

Manufactured by: 

 

 

 

PRIMARY FLUID  1050 Cooke Blvd., Burlington, Ontario, L7T 4A8

 

SYSTEMS INC. 

Tel: (905) 333-8743 

Fax: (905) 333-8746

 

Call Toll Free:  1-866-324-6422

 

E-Mail: 

[email protected] 

http:www.ecovalve.ca

 

Содержание ECO-110

Страница 1: ...iled information and instructions that must be read understood and followed to ensure that the equipment is installed operated and serviced in an appropriate manner Failure to do so before using may result in hazardous consequences and or improper operation Manufactured by PRIMARY FLUID 1050 Cooke Blvd Burlington Ontario L7T 4A8 SYSTEMS INC Tel 905 333 8743 Fax 905 333 8746 Call Toll Free 1 866 32...

Страница 2: ...ring provides consistent pressure adjustments through the range 7 150 PSIG Eco valve is available in several configurations to meet your needs such as threaded socket flanged union in DIN BSPT and American Standard Built in downstream manual air release for ease of pump priming Built in anti siphon Back Pressure Valve Anti siphon Diaphragm Back Pressure Valves serve two primary functions The first...

Страница 3: ...he valve body the ports are normally not drilled or tapped for a gauge connection See gauge installation instructions on page 5 Caution The gauge port is solely for the installation of the gauge and cannot be used for the bleeding or venting of the system Improper operation and or hazardous consequences could result See gauge installation instructions Pressure Relief Valves Reason for Selection an...

Страница 4: ... pump and should be located as close as possible to the metering pump The valve is of an two port design and is required to be installed on a branch tee for piping back to the supply tank or feed side of the pump Never install shut off isolation valves between pump discharge and in line pressure relief valves When using in conjunction with a back pressure control valve always install back pressure...

Страница 5: ...n of the diaphragm on the seat To adjust the valve to relieve air or gas downstream 1 Back off lock nut located beneath the colour coded handle 2 Turn handle counter clockwise until approximately 1 inch of thread is exposed 3 At this adjustment the spring has relieved all tension from the diaphragm allowing air or gas to be vented downstream ...

Страница 6: ... examples only Consult your engineering department for the appropriate installation for your application or call the factory for advice Example A Solenoid Driven Pumps Rated Under 150 psig Example B System arrangement for solenoid driven above 150 psig or motor driven pumps ...

Страница 7: ...7 ...

Страница 8: ...0 1 S S valve 125 1 S S valve 150 1 S S valve 200 2 S S valve Material PVC polyvinyl chloride CPVC Corzan PP polypropylene PVDF polyvinyldene fluoride S S6 316L stainless steel Colour B Blue 1 valve S Silver 1 valve BL Black 1 valve W White 2 valve O Ring seal V viton E EPDM T PTFE encapsulated viton Material PVC polyvinyl chloride CPVC Corzan 15 EVUI 15 PP polypropylene PVDF polyvinyldene fluorid...

Страница 9: ...ngly The following factors will apply Temperature Correction Factors Thermoplastics Operating Temperatures Factors F C PVC CPVC PP PVDF 70 21 1 00 1 00 1 00 1 00 80 27 1 00 1 00 1 00 1 00 90 32 1 00 1 00 1 00 1 00 100 38 90 1 00 1 00 1 00 110 43 83 1 00 91 1 00 115 46 75 1 00 87 1 00 120 49 66 1 00 83 1 00 125 52 58 97 79 1 00 130 54 50 95 75 1 00 140 60 33 90 66 1 00 150 66 NR 80 60 97 160 71 NR ...

Страница 10: ...10 ...

Страница 11: ...nts and instructions set forth herein are based on the best information and practices known to Primary but it should not be assumed that every acceptable safety procedure is contained herein Of necessity Primary cannot guarantee that actions in accordance with such statements and instructions will result in the complete elimination of hazards and it assumes no liability for accidents that may occu...

Страница 12: ...12 Notes ...

Отзывы: