background image

Page  1 of 8

Model  CDMD   

I&O IN-159

Installation,
Operating,
and
Maintenance
Manual

CD Mag Drive

Caution:
Before installing,
repairing or performing
maintenance on this
pump, read these
instructions completely.

      Photo is pasted on
      Need iacdmd.dxf
      from engineering

Installation

Electrical

WARNING!
Ground motor before
connecting to electrical
power supply!  Failure to
ground motor can cause
severe or fatal electrical
shock hazard!

Do not ground to gas
supply line!

Disconnect power to
motor before working
on motor or pump!

Match voltage to
nameplate voltage on
motor.  Incorrect voltage
can cause fire or
seriously damage motor,
voiding warranty.

                    Form IN-159

Close Coupled -  Motor Pumps

These pumps require no
special care in mounting,
although it is suggested that
they be firmly bolted to a level
surface.  Adequate air
movement over motor will
help prevent overloads.

Base Mounted Pumps
(Pedestal Pumps)

These pumps must be mounted
on a rigid steel base that will
not warp or flex.  Each pump
must be mounted such that 

the

pump shaft centerline is on
center with the driver shaft
centerline.  

Pads and/or shims

will be required on either
pump, driver or both.  The two
shafts should not touch each
other and the distance between
them depends on the coupling
used to connect them.

Misalignment will cause
bearing failure and void
warranty.  

Pumps are rough

aligned at the factory but must
be realigned after shipment
and installation.  Pulley driven
pumps must have pulleys in
line and good belt tightness
practices followed.

Direction of Rotation

Note: Motor shaft rotation is
viewed from the suction end of
pump.  A rotational arrow is
shown on the front of the
pump volute casing.  Incorrect
rotation can cause pump
damage, failure or reduced

Содержание CD Mag Drive

Страница 1: ...e firmly bolted to a level surface Adequate air movement over motor will help prevent overloads Base Mounted Pumps Pedestal Pumps These pumps must be mounted on a rigid steel base that will not warp o...

Страница 2: ...a valve globe ball or other adjustable and non leak type in the discharge line close to the pump The valve may be closed during system repairs to prevent backflow By installing a check valve in the d...

Страница 3: ...r installation g Pump cavitation h Plugged or damaged impeller 3 Excessive noise or vibration during operation Check for a Motor bearing failing b Pump cavitating c Impeller rubbing volute 4 Leaking m...

Страница 4: ...net assembly to shaft 13 Remove shaft F and thrust washer N from magnet assembly 14 Loosen both setscrews L which secure the Bushing sleeve J into the separator plate using 1 8 Allen wrench Remove the...

Страница 5: ...net impeller assembly back from the volute to remove play from the assembly Insert a 0 025 angled feeler gauge into the pump suction between the top of the impeller vane and the internal volute face P...

Страница 6: ...Page 6 of 8 Price Pump Company 1 Pump Way w P O Box Q w Sonoma CA 95476 w 707 938 8441 w Fax 707 938 0764 put in the parts list here when complete...

Страница 7: ...Page 7 of 8 Price Pump Company 1 Pump Way w P O Box Q w Sonoma CA 95476 w 707 938 8441 w Fax 707 938 0764 Outline Drawing parts list...

Страница 8: ...re a part of this agreement E The manufacture and inspection of products and parts shall be to Seller s Engineering and Quality Assurance standards plus such other inspections tests of documentation a...

Отзывы: