Configure C3 Module(s) for VL5+ Luminaires:
Lamp power for a VL5+™ Wash Luminaire is provided by either a
conventional dimmer or a C3™ dimmer module installed in a Series 300™
Modular Rack.
The C3 module can be configured in two different output modes to
accommodate both the 1000 watt and 1200 watt versions of the 120V
incandescent lamps used with VL5+ luminaires. The 8.33 mode is used with
1000W/120V lamps and the 10.0A mode is used with 1200W/120V lamps.
A 0W shunt (blue programming jumper) installed at PCB determines the
mode.
CAUTION:
Do not change mode with power applied to module.
Step 1. Determine required mode by checking lamp type in the luminaire.
Step 2. At C3 module PCB, install 0W shunt (blue programming jumper) on header marked 8.33A
for 1000W operation or 10.0A for 1200W operation.
Figure 2-11: C3 Module PCB
Note:
Since the C3 module does not have its own built-in brightness curve, the module must be used
in conjunction with an SPC-36™ controller, which has the brightness curve in its operating system.
The SPC-36 controller outputs 0 to +10 volts DC, which corresponds to 0% and 100% output
respectively. Refer to the Series 300™ Modular Rack Service Manual (02.9640.0010) for more
information.
Blue Programming
Jumper
Содержание VL5+
Страница 1: ...USER MANUAL 02 9634 0002 VL5 Wash Luminaire VL5Arc Wash Luminaire ...
Страница 10: ...VL5 SERIES WASH LUMINAIRE USER MANUAL viii 02 9634 0002 Notes ...
Страница 24: ...VL5 SERIES WASH LUMINAIRE USER MANUAL 14 02 9634 0002 Notes ...
Страница 60: ...VL5 SERIES WASH LUMINAIRE USER MANUAL 50 02 9634 0002 Notes ...
Страница 72: ...VL5 SERIES WASH LUMINAIRE USER MANUAL 62 02 9634 0002 Notes ...
Страница 73: ...02 9634 0002 63 APPENDIX A Technical Specifications ...
Страница 76: ...VL5 SERIES WASH LUMINAIRE USER MANUAL 66 02 9634 0002 Notes ...
Страница 82: ...VL5 SERIES WASH LUMINAIRE USER MANUAL 72 02 9634 0002 Notes ...