Pressalit SCT 3000 Скачать руководство пользователя страница 1

R8572313 (AUS)
R8572318 (AUS)
R8582313
R8582318
R8592313 (US)
R8592318 (US)

SCT 3000

Shower change table – 

Operation and maintenance manual

en

Bruseleje – 

Brugs- og vedligeholdelsesvejledning

dk

Duschliege – 

Gebrauchs- und Pflegeanleitung

de

Table de douche et de change – 

Manuel d’utilisation et d’entretien

fr

Douchebrancards – 

Gebruiks- en onderhoudshandleiding

nl

Duschbrits – 

Bruks- och underhållsanvisning

sv

Dusjstellebord – 

Bruks- og vedlikeholdsveiledning

no

Camilla de ducha - 

Instrucciones de uso y mantenimiento

es

Stół prysznicowy

 – Instrukcja obsługi i konserwacji

pl

洗澡床

 - 

操作和维护手册

中文

ةنايصلاو ليغشتلا ليلد

 – مامحتسلاا ةلواط

ةيبرعلا

Содержание SCT 3000

Страница 1: ...ning dk Duschliege Gebrauchs und Pflegeanleitung de Table de douche et de change Manuel d utilisation et d entretien fr Douchebrancards Gebruiks en onderhoudshandleiding nl Duschbrits Bruks och underh...

Страница 2: ...ig voor materiaal en fabricagefouten Onder voorbehoud van drukfouten technische wijzigingen en modelafwijkingen sv Garantin g ller i 3 r fr n fakturadatum f r material och fabrikationsfel Med reservat...

Страница 3: ...3 REF R8572313 R8582313 R8592313 R8572318 8582318 R8592318...

Страница 4: ...4 REF 230V R8582313 R8582318 REF 120V R8592313 R8592318 REF 230V R8572313 R8572318 Max P U Max I R8582313 R8582318 R8572313 8572318 75W 230V 0 3 R8592313 R8592318 36W 120V 0 3...

Страница 5: ...DD YY MM DD U XXXV XX XX Hz IPXX P X W I XXA RZZZZYYYXXX X 01 0XXXXXXXXXXXXX 10 YYMMDD xxx kg xxx lbs xxx kg xxx lbs xxx kg xxx lbs 2 min 18 min Pressalit A S Pressalitvej 1 DK 8680 Ry 45 8788 8777 w...

Страница 6: ...Montageanleitung DE Mounting instruction EN Notice de montage FR Montage voorschrift NL Monteringsanvisning SV Monteringsveiledning NO Subject to alteration without further notice Ret til ndringer for...

Страница 7: ...7 mm 123 798 992 1057 750 1410 1200 230 R8572313 R8582313 R8592313 123 798 992 750 1910 1630 230 1057 R8572318 8582318 R8592318...

Страница 8: ...8 inch 4 88 31 38 39 29 5 55 5 47 25 9 41 63 R8572313 R8582313 R8592313 4 88 31 38 39 29 5 75 25 64 13 9 41 63 R8572318 8582318 R8592318...

Страница 9: ...leaning 17 To remove limescale 17 Disinfection 18 Maintenance 19 Maintenance inspection 19 Product label 21 Trouble shooting 23 Electromagnetic compatibility 24 Electromagnetic immunity 25 Electromagn...

Страница 10: ...ch if not avoided may result in minor or moderate injury It may also be used to alert against unsafe practices IMPORTANT IMPORTANT indicates important information about handling and use of the product...

Страница 11: ...ad and understand the manual completely before use Keep the manual close to the unit Comply with this manual to avoid accidents involving serious personal injury Never use or handle this product in ot...

Страница 12: ...ch as a bathroom or wash room The product is intended to be used at room temperature in private homes nursing homes and hospitals under normal working conditions Contraindications for use Use of the u...

Страница 13: ...ody when folding it up and down to avoid the risk of damage The built in gas cylinders make it easy to fold the table up against the wall after use NOTICE Any serious incident that has occurred in rel...

Страница 14: ...s locked To fold the safety rail away Turn the locking knob one way or another to release the safety rail Push the safety rail back to the underside of the table until you hear a click indicating that...

Страница 15: ...he floor it can be adjusted between 300 and 1000 mm above the floor The height adjustment is controlled by the wired remote control unit Press and hold the up button to raise the table and press and h...

Страница 16: ...cket down to hold the pad in the upright position The end pads are interchangeable and can be placed at either end of the table 1 2 CAUTION Never let a person lie on the shower table without the pads...

Страница 17: ...ds 1 2 2 2 2 To remove limescale To remove limescale marks on the aluminium parts use 3 parts 30 household vinegar to 7 parts water and afterwards wipe the parts with a cloth wrung out in clean water...

Страница 18: ...disinfecting or de scaling agent and comply with instructions for safe use dilution rinsing drying handling and storage of the agent Disinfection When using the shower table for multiple patients it...

Страница 19: ...positions by raising the product to its full height and then lowering it to its lowest position so that the internal parts are lubricated It is recommended that maintenance inspection is done once a...

Страница 20: ...k the wall brackets and tighten if necessary Oil moving parts especially the sliding brackets 2 2 2 2 5 6 4 3 3 Disconnect mains before removing the covers Check all electrical connections to the cont...

Страница 21: ...D xxx kg xxx lbs xxx kg xxx lbs xxx kg xxx lbs 2 min 18 min Pressalit A S Pressalitvej 1 DK 8680 Ry 45 8788 8777 pressalit com REF 21 22 Article number Production date Maximum user weight Medical devi...

Страница 22: ...electric shock Do not dispose as unsorted municipal waste The product should be collected separately and returned to the designated recycling service Product weight Batch code This product does not c...

Страница 23: ...lit A S or your local dealer The product will not work even though the remote control is used correctly Fault in power supply Check that all wires and plugs are intact and correctly connected Contact...

Страница 24: ...ntrol spiral cable Approx 5 m 197 extended WARNING Use of accessories transducers and cables other than those specified or provided by the manufacturer could result in increased electromagnetic emissi...

Страница 25: ...est level EN 61000 4 2 8 kV contact 2 4 8 15 kV air Radiated RF electromagnetic field The product must not be affected by radiating RF signals for example from a mobile phone or radio that could cause...

Страница 26: ...50 duty cycle square wave 870 MHz 28V m 18 Hz PM 50 duty cycle square wave 930 MHz 28V m 18 Hz PM 50 duty cycle square wave 1720 MHz 28V m 217 Hz PM 50 duty cycle square wave 1845 MHz 28V m 217 Hz PM...

Страница 27: ...omponents defective Test standard Immunity test level EN 61000 4 6 3 V 6 V in ISM bands and amateur radio bands 0 15 to 80 MHz 80 AM at 1 kHz Voltage dips The product must not initiate or limit action...

Страница 28: ...sion test class and group EN 55011 Class B group 1 Harmonic current emissions The product must not unintentionally draw power from the grid Test standard Emission test class and group IEC 61000 3 2 Cl...

Страница 29: ...at it can be used again and again even in the case of anodised products as the anodised layer is a natural part of the aluminium Steel Steel can be recycled by being re melted and included as a second...

Отзывы: