background image

TROUBLESHOOTING

You can solve many common air conditioner problems easily, saving you the cost of a service call. Try the suggestions below to 
see whether you can solve your problem without outside help.

Air conditioner will not operate

The power supply cord is unplugged. Plug into grounded 
3 prong outlet. See “Electrical Requirements.”

The power supply cord trips (Reset button will pop out). 
Press and release RESET (listen for click; Reset button will 
latch and on some devices, a green light will turn on) to 
resume operation.

A household fuse has blown or circuit breaker has 
tripped. 
Replace the fuse or reset the circuit breaker. See 
“Electrical Requirements.”

Depending on model, the Power button has not been 
pressed or the Fan Speed control is turned to Off. 
Press 
POWER button or turn the FAN SPEED control to an active 
setting.

The local power has failed. Wait for power to be restored.

Air conditioner blows fuses or trips circuit breakers

Too many appliances are being used on the same circuit. 
Unplug or relocate appliances that share the same circuit.

Time-delay fuse or circuit breaker of the wrong capacity 
is being used. 
Replace with a time-delay fuse or circuit 
breaker of the correct capacity. See “Electrical 
Requirements.”

An extension cord is being used. Do not use an extension 
cord with this or any other appliance.

You are trying to restart the air conditioner too soon after 
turning the unit off. 
Wait at least 3 minutes after turning the 
unit off before trying to restart the air conditioner.

Air conditioner power supply cord trips (Reset button 
pops out)

Disturbances in your electrical current can trip (Reset 
button will pop out) the power supply cord.
 Press and 
release RESET (listen for click; Reset button will latch and on 
some devices, a green light will turn on) to resume operation.

An electrical overloading, overheating, pinching or aging 
can trip (Reset button will pop out) the power supply 
cord.
 After correcting the problem, press and release RESET 
(listen for click; Reset button will latch and on some devices, 
a green light will turn on) to resume operation.

NOTE: A damaged power supply cord must be replaced with a 
new power supply cord obtained from the product manufacturer. 
A damaged power supply cord must not be repaired.

Air conditioner seems to run too much

The current air conditioner replaced an older model. The 
use of more efficient components may cause the air 
conditioner to run longer than an older model, but the total 
energy consumption will be less. Newer air conditioners do 
not emit the “blast” of cold air you may be accustomed to 
from older units, but this is not an indication of lesser cooling 
capacity or efficiency. Refer to the efficiency rating (EER) and 
capacity rating (in BTU/hr.) marked on the air conditioner.

The air conditioner is in a heavily occupied room, or heat-
producing appliances are in use in the room. 
Use exhaust 
vent fans while cooking or bathing and try not to use heat-
producing appliances during the hottest part of the day. A 
higher capacity air conditioner may be required, depending 
on the size of the room being cooled.

Air conditioner cycles on and off too much or does not 
cool

The Mode is set to Power Saver (on some models). Use 
Power Saver only when you are away from home or asleep, 
since the fan does not circulate the room air continuously. 
Use Low, High or Turbo for your best comfort.

The air conditioner is not properly sized for your room. 
Check the cooling capabilities of your room air conditioner. 
Room air conditioners are not designed to cool multiple 
rooms. 

The filter is dirty or obstructed by debris. Clean the filter. 

The inside evaporator and outside condenser coils are 
dirty or obstructed by debris.
 See “Annual Maintenance.”

There is excessive heat or moisture (open container 
cooking, showers, etc.) in the room.
 Use a fan to exhaust 
heat or moisture from the room. Try not to use heat-
producing appliances during the hottest part of the day.

The louvers are blocked. Install the air conditioner in a 
location where the louvers are free from curtains, blinds, 
furniture, etc.

The outside temperature is below 65°F (18°C). Do not try to 
operate your air conditioner in the cooling mode when the 
outside temperature is below 65°F (18°C).

The temperature of the room you are trying to cool is 
extremely hot. 
Allow extra time for the air conditioner to cool 
off a very hot room.

Windows or doors to the outside are open. Close all 
windows and doors.

The Exhaust control is set to OPEN (on some models). 
Push the Exhaust control CLOSED for maximum cooling.

Depending on model, the Temp/Time or Temperature 
control is not at a cool enough setting. 
Adjust the TEMP/
TIME control to a cooler setting by pressing the minus button 
to reduce the temperature or adjust the TEMPERATURE 
control to a cooler setting by turning the knob clockwise. Set 
the FAN SPEED control to highest setting (Turbo or High, 
depending on model).

Water drips from cabinet into your house

The air conditioner is not properly leveled. The air 
conditioner should slope slightly downward toward the 
outside. Level the air conditioner to provide a downward 
slope toward the outside to ensure proper drainage. See the 
Installation Instructions. 

NOTE: Do not drill a hole in the bottom of the metal base and 
condensate pan.

7

Содержание PWA1210G

Страница 1: ...ROOM AIR CONDITIONER AIRE ACONDICIONADO VENTANA USER MANUAL MANUAL DE USUARIO PAC9039G PWA1210G ...

Страница 2: ...USE 2 Starting Your Air Conditioner Digital Control 2 Starting Your Air Conditioner Mechanical Control 5 Normal Sounds 6 AIR CONDITIONER CARE 6 Cleaning the Air Filter 6 Cleaning the Front Panel 6 Repairing Paint Damage 6 Annual Maintenance 6 TROUBLESHOOTING 7 ...

Страница 3: ...d on your appliance Always read and obey all safety messages This is the safety alert symbol This symbol alerts you to potential hazards that can kill or hurt you and others All safety messages will follow the safety alert symbol and either the word DANGER or WARNING These words mean IMPORTANT SAFETY INSTRUCTIONS WARNING To reduce the risk of fire electrical shock or injury when using your air con...

Страница 4: ... power failure your air conditioner will operate at the previous settings when the power is restored Lights next to the touch pads on the air conditioner control panel indicate the selected settings Delay 1 24hr Delay timer Decrease Mode select Fan speed Decrease Temperature set Increase and Decrease Remote Control Delay timer Increase Auto Fan on Fan speed Increase Unit power on off The display a...

Страница 5: ...set the air conditioner to Cool Energy Saver or Fan Only mode Delay Pads Delay ON When the air conditioner is off it can be set to automatically come on in 1 to 24 hours at its previous mode and fan settings Delay OFF When the air conditioner is on it can be set to automatically turn off in 1 to 24 hours How to set Press the Delay 1 24hr pad on the unit or the pad on the remote control Each touch ...

Страница 6: ...the Fan Only Mode at Low Med or High fan speed to provide air circulation and filtering without cooling Since fan only settings do not provide cooling a Set temperature cannot be entered The room temperature will appear in the display NOTE Auto Fan Speed cannot be used when in the Fan Only Mode Energy Saver Mode The fan will cycle on and off with the compressor This results in wider variations of ...

Страница 7: ...ing Select High Cool with the TEMPERATURE control at the highest number available on your knob For Quieter Nighttime Cooling Select Low Cool with the TEMPERATURE control at midpoint TEMP Control The TEMP control is used to maintain the room temperature The compressor will cycle on and off to keep the room at the same level of comfort When you turn the knob to a higher number the indoor air will be...

Страница 8: ... filter down into filter door and closing filter door CleaningtheFrontPanel 1 Unplug air conditioner or disconnect power 2 Clean front panel with a soft damp cloth 3 Air dry front panel completely 4 Plug in air conditioner or reconnect power RepairingPaintDamage Check once or twice a year for paint damage This is very important especially in areas near oceans or where rust is a problem If needed t...

Страница 9: ... the blast of cold air you may be accustomed to from older units but this is not an indication of lesser cooling capacity or efficiency Refer to the efficiency rating EER and capacity rating in BTU hr marked on the air conditioner The air conditioner is in a heavily occupied room or heat producing appliances are in use in the room Use exhaust vent fans while cooking or bathing and try not to use h...

Страница 10: ... Su Aire Acondicionado con Control Digital 2 Iniciar Su Aire Acondicionado con Control Mecánico 6 Sonidos Normales 7 Cuidado del Aire Acondicionado 7 Limpieza del Filtro de Aire 7 Limpieza del Panel Frontal 8 Reparación del Daño de la Pintura 8 Mantenido Anual 8 Solución de Problema 9 ...

Страница 11: ... nosotros hemos proveido muchos mensajes importantes sobre seguridad Por favor lea y obedezca los mensajes Éste es el símbolo de alerta de seguridad Este símbolo advierle de los peligros potenciales que pueden matar o hacerle daño a usted y los demás Todos los mensajes de seguridad seguirán el símbolo de alerta o la palabra PELIGRO o ADVERTENCIA cuales significan Graves concecuencias incluso la mu...

Страница 12: ...ión anterior cuando se reinicie de nuevo Iniciar Su Aire Acondicionado con Control Digital Luces cerca de los botones en el panle de control indican la configuración seleccionada Delay 1 24hr Delay timer Decrease Mode select Fan speed Decrease Temperature set Increase and Decrease Delay timer Increase Auto Fan on Fan speed Increase Unit power on off 2 Simpre se mostra la temperatura ambiente en la...

Страница 13: ... ajustaráel tiempo retardado Velocidad del Ventilador Se usa para ajustar la velocidad del ventilador de modos LOW baja Med mediano High alta o Auto Presione Fan y Fan para ajustar la velocidad a la que deseada o AUTO a activar esta función MODE MODO Se usa para elejir modos Cool Energy Saver o Fan Only mode DELAY tiempo retardado DelayON cuando la unidad está apagada se puede reencender autométic...

Страница 14: ... termostato Descripciones de Enfriamiento Para enfriamiento normal selecione el modo Cool y High Med Fan con una temperatura mediano Para enfriamiento máximo selecione el modo Cool y High Fan con una temperatura ajustada baja Para Enfriamiento para dormir selecione el modo Cool y Low Fan con una temperatura ajustada mediana NOTA cuando el AC se reencende y está ajustado al modo de enfriamiento o s...

Страница 15: ...idad del ventilaor autométicamente se ajustara con el gol de proveer confort óptimo según la temperatura ajustada Por eso si la habitación nesecita más enfriamiento la velocidad del ventilador se suba automáticamente Viceversa NOTA Auto Fan del ventilador no se puede usar en el modo de Fan Only Características de Restablecimiento En el caso de pausa o interrupción de energía la unidad se puede enc...

Страница 16: ...nfriamiento normal selecione el modo Cool y High MED Fan con una temperatura mediano Para enfriamiento máximo selecione el modo Cool y High Fan con una temperatura ajustada baja Para Enfriamiento para dormir selecione el modo Cool y Low Fan con una temperatura ajustada mediana TEMP Control El control TEMP se usa para mantener la temperatura ambiente El compresor se encende y se apaga para mantener...

Страница 17: ...ara proveer a usted años de servicios dependable Esta sección le introducirá el método de limpiar y cuidar su aire acondicioando correctamente Llame al detallista autorizado local para examinar la máquina anualmente Recuérdele este gasto es su responsibilidad Limpieza del Aire Acondicionado a Un filtro limpio ayudará a remover pere el aire acondiconado sin el filtro Apaque el aire acondicionado rl...

Страница 18: ... de que emplazarlo de nuevo para asegurar eficacia máxima Emplaze el filtro p L 1 Desenchufe el aire acondicionad 2 Limpie el frente del panel con un paño suave y húmedo 3 Seque el frente del panel completemente con aire 4 Enchufe el aire acondicionado o reconecte con la el R Examine una vez o dos cada añ especialmente en areas cerca del mar o areas en que corossión es un problema S necesario use ...

Страница 19: ... el control de la velocidad del ventil se está apagado Presione el botón de Energía o ajuste el control de velocidad del ventilador a una configuración activa F interruptado Demasiados ultilizandos Desenhufe o recoloq los domésticos que comparten el mismo circuito tiempo retardad interruptor del circuito de la incorrecta capacidad se están ultilizando Cambie el fusible interruptor Refiérase a requ...

Страница 20: ... producen calor durante el tiempo más caliente del día las Rejillas están bloqueadas la temperatura fuera es baja de 65 F 18 C en este caso no selecione el modo COOL la temperatura de la habitación quiere enfriar es extrematament caliente Espere abiertas el control de Escape está seleccionado en a modelos Cerre este contr conseguir el enfriamiento Depende del modelo la configura de enfriamiento de...

Страница 21: ...66129906829 ...

Отзывы: