5.5
Modbus address list
Parameter
Start address (hex) Byte count
Data type
Unit
Output voltage setting
00 00
4
Single-precision
floating-point
value
V
Output current setting
00 04
4
A
⚫
Function code available: 03, 10
⚫
Control authority (start address 00 09) should be set 01 (remote control) to
permit writing.
Parameter
Start address (hex) Byte count
Data type
Unit
Output setting
00 08
1
Control code
-
00
Stop output
01
Start output
⚫
Function code available: 03, 10
⚫
The control authority (start address 00 09) should be set to 01 (remote control)
to permit writing.
Parameter
Start address (hex) Byte count
Data type
Unit
Control authority
00 09
1
Control code
-
00
Local control
01
Remote control
⚫
Function code available: 03, 10
Parameter
Start address (hex) Byte count
Data type
Unit
Modbus ID
00 0A
1
Control code
-
⚫
Function code available: 03, 10
⚫
The control authority (start address 00 09) should be set to 01 (remote control)
to permit writing.