About
Standard access codes are used across Precor cardio product lines to access a set of com-
mon service software functional modes used to retrieve equipment product and usage inform-
ation, manage club settings, and hardware maintenance validation/diagnostic test software.
Each mode is assigned a unique service access code that is entered into the console to begin
the functional mode. There are three functional modes: Hardware Validation, Club Para-
meters, and Information Display:
l
Hardware Validation is a set of functional diagnostic tests used to troubleshoot and
verify proper operation.
l
Club Parameters also referred to as Club Settings are used manage and configure the
usage of the machine.
l
Information Display provides information about the equipment usage, hardware, soft-
ware, and error log data.
The user interface, available information, settings, etc. will vary based on the console model -
base configuration. Make sure to use the information and instructions for your particular con-
sole application. Consoles that support standard service access codes include:
• Standard Consoles
• P30 console
• P10 consoles
• P80 console
• P20 console
Service Access Codes
The following table lists the standard service access codes and associated functional mode.
SERVICE
ACCESS CODE
SERVICE MODE
FUNCTION
5,1,7,6,5,7,6,1
Hardware Validation
Diagnostic tests.
5,6,5,1,5,6,5
Club Parameters
Configure machine and workout
parameter limits.
6,5
‡
Information Display
‡
View usage, SW, and Error Log
information.
Note:
‡
Access code 65 not used on the P80, use access code 51765761.
Accessing the Service Software
The process to access the service code functional mode varies between console models. Go
to instructions listed below for your particular console to learn how to access the service
P82 Console
20
3 Standard Service Software
About