System Tests menu
System Tests menu
menu:
Service menu (51765761) > System Settings > System Tests
.
Machine diagnostics tests to verify system hardware operation.
SYSTEM TESTS
MENU
TEST DESCRIPTION
Brake Test
menu:
System Tests > Brake Test
If the brake is operational, provides the following operating inform-
ation:
l
PWRB XXX: The current power bits.
l
RPM: Brake generator RPM.
l
VBUS XX: Bus Voltage used to drive the brake.
l
M-AMPS XX: DC brake current.
Battery Test
menu:
System Tests > Battery Test
Shows the current battery voltage level as "XX.X VDC Y".
Where:
XX.X is the measured DC battery voltage (nominal 12.6 - 14.6
Vdc).
There can be an additional "Y" suffix indicating the following con-
dition:
"C" an external AC charger is connected.
"L" the battery is low (less than 11.5 Vdc).
"CL" charger is connected and the battery is low.
SPM Test
(EFX, AMT only)
menu:
System Tests > SPM Test
SPM "Strides per Minute" test metrics:
l
Pulse: current pulse count.
l
Minimum: minimum pulse count.
l
Maximum: maximum pulse count.
CrossRamp Test
(EFX, AMT only)
menu:
System Tests > CrossRamp Test
Manually run the lift motor to raise/lower the crossramp through full
range, levels 1 to 20.
Contact Precor Customer Support at [email protected] or 800.786.8404 with
any questions.