2 Gently snap the front edge of the top cover into place, using the heel of your hand if necessary.
3 Wrap the gasket around the center fame column below the heart rate sensor grips and then fit it into the
top cover. Make sure that the surfaces and edges of the gasket are flush with those on the top cover.
Replacing a Belt Guard
Finger Guard Replacement Procedure
Upper Arm Cover Removal
FIGURE 20: UPPER ARM COVERS
1 Remove the four screws that fasten the inside upper arm covers to the upper arm.
2 Remove the screw that fasten the outside upper arm covers to the upper arm.
3 Remove the inside and outside covers from the upper arm.
4 Repeat the process for the remaining upper arm covers.
FIGURE 21: UPPER ARM COVER SCREW LOCATIONS