Possible Causes
1
Poor or intermittent connection in the lift position sensor (potentiometer).
2
Bad lift position sensor
3
Bad lower control module.
Possible Remedies
1
This is the most common cause of an error 44. Verify all wiring and connections associated with
the lift position potentiometer. Repair or replace wiring or connections as appropriate. Because of
the nature of the revolution sensor an error 44 is rarely associated with it.
2
Operate the lift in the diagnostics while monitoring the lift position number being displayed. If the
reading is erratic and makes large changes in readings the lift position potentiometer is probably
bad. Replace the lift motor.
3
If there is actual lift motion without a manual or program control lift command having been issued,
replace the lower control module.
Error 45 - Lift Moving in Wrong Direction
Description
The lift control system has detected that the lift is moving in the opposite direction of the issued lift command.
Possible Causes
1
Lift Motor hysteresis.
Содержание AMT12 base
Страница 250: ......
Страница 254: ... Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 254 ...
Страница 270: ... Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 270 ...
Страница 272: ... Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 272 ...
Страница 273: ... Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 273 ...
Страница 274: ... Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 274 ...
Страница 275: ... Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 275 ...
Страница 276: ... Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 276 ...