12 Check the generator belt tension, if not within specification continue with the following adjustment steps.
See
Drive Belt Gauge Instructions
.
Generator Belt Tension Specification
Generator Belt
Tension
new
85 +/- 5 lbs (38.6 +/- 2.3 kgs)
used*
60 - 75 lbs (27.2 - 34 kgs)
Note: * More than 1 hour of use.
13 Loosen or tighten the 1/4-20 X 3 generator adjustment nut and bolt until the belt gauge reads
approximately 90 lbs.