3 Fitting and installing
© Precitec GmbH & Co. KG • EN 09/2019
3 - 31
3.4
Installation
3.4.1
Connecting the cutting gas system
(trained personnel only)
Fig. 3-7
Installation: Connections - Cutting gas
Cutting gas
Attention – Pressure tightness!
Please ensure that all connections on the laser head that are not being used
are closed with screw plugs; otherwise the laser head will no longer work
correctly and gas or liquids can get into it.
1
LC-
BA-
oG
as
G1/8
(8 mm deep)
1
Cutting gas, G 1/8 connection
Attention – Cutting gas!
Only clean, dry cutting gas can be used.
Cutting gas quality in compliance with ISO 8573-1:2010; Solid particles - Class 2,
Water - Class 4, Oil - Class 3 (see
The maximum pressure on the laser head is 25 bar
(2.5 MPa)
.
Connect the cutting gas hose to connection (1)
(G1/8, 8 mm deep)
.
Precitec recommends connecting the cutting gas using hoses with the largest possible
diameter.
When delivered, the connections are closed with dummy plugs.
Attention:
Sealing the fittings - sealing tape or sealing material is not permitted!