DESCRIPTION:

SP-500 is an electronically activated trap priming device. Primer functions in conjunction with EMS, delivering potable 

water across an air gap funnel.

 

CAUTION: SP-500 

should not be defined as pressure feed trap priming system. Device must be installed a minimum 

of 12" above flood level of device being served. Trap primer should be mounted one foot above the finished floor for 

every 20 feet of trap priming line, measured from bottom of air gap.

OPERATION:

EMS activated solenoid valve discharging potable water to P-trap

INSTRUCTIONS PERTAINING TO A RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS

*** IMPORTANT SAFETY INSTRUCTIONS ***

*** SAVE THESE INSTRUCTIONS ***

WARNING - When using electric appliances, basic precautions should always be followed, including the 

following:

 

a) Read all of the instructions before using the appliance.

 

b) Do not contact moving parts.

 

c) Only use attachments recommended or sold by the manufacturer

 

d) Do not use outdoors.

To disconnect turn all controls to the off position, then remove from connection.

Disconnect power before servicing or cleaning.

Do not operate any appliance with a damaged cord, or after the appliance malfunctions or is dropped or 

damaged in any manner.  Return appliance to the nearest authorized service facility.  For examination, repair, 

or electrical or mechanical adjustment.

 

e) For a permanently connected appliance - Turn the power switch to the off position when the appliance is not in 

 

     use and before servicing or cleaning.

 

f) For a grounded appliance - Connect to a properly grounded outlet only.

    See grounding instructions.

GROUNDING INSTRUCTIONS

This appliance must be connected to a grounded metal, permanent wiring system; or an equipment-grounding 

conductor must be run with the circuit conductors and connected to the equipment-grounding terminal or lead on the 

appliance.

SAVE THESE INSTRUCTIONS

INSTALLATION:

1)  Primer’s minimum elevation  above floor rim of drain served shall be one foot. Device must be installed a 

minimum of 12" above flood level of device being served. Trap primer should be mounted one foot above the   

finished floor for every 20 feet of trap priming line, measured from bottom of air gap.

2)  Solo-prime must be installed in an accessible location. For access door applications use 8” x 14” model D814 

prime coat or stainless steel.   

3)  Connect ½” male NPT fitting (primer supply) to fresh water line, using Teflon tape. Connect priming discharge 

line (minimum ½”) to inlet side of floor drain being served (not supplied).  Ensure discharge line is properly 

sloped downward to the discharge point. 

4)  Connect primer drain line, distribution unit or PM manifold to system, ensure assembly is plumb and square.

5)  Wire primer to Energy Management System, follow N.E.C. and local codes.

 

 

 

 

1044

WATER HAMMER 

ARRESTORS

TEMPERA

 ANTI-SCALD VALVES

BAC-2-BAC

MANIFOLDS

TRAP PRIMER VALVES 

AND MANIFOLDS

THERMOSTATIC 

MIXING VALVES 

Solo Prime Electronic Trap Priming System

Installation & Maintenance Instructions