PD2-6210
Helios Large Display Analog Input Batch Controller Instruction Manual
5
Ordering Information
Standard Models
85-265 VAC Model 12-24 VDC Model Options Installed
PD2-6210-6H2
PD2-6210-7H2
2 Relays
PD2-6210-6H7
PD2-6210-7H7
4 relays & 4-20 mA output
Accessories
Model
Description
PDA6260
Pipe Mounting Kit
PDA7485-I
RS-232 to RS-422/485 isolated converter
PDA7485-N
RS-232 to RS-422/485 non-isolated converter
PDAPLUG2
Plastic Conduit Plug
PDX6901
Suppressor (snubber): 0.01 µF/470
, 250 VAC
Specifications
Except where noted all specifications apply to operation at +25°C.
General
Display
Main display: 1.8" (46 mm) high,
red LEDs
6 digits per line (-99999 to
999999), with lead zero blanking
Display
Intensity
Eight user selectable intensity
levels
Display
Update Rate
5/second (200 ms)
Overrange
Display flashes
999999
Underrange
Display flashes
-99999
Display
Assignment
Display lines 1 & 2 may be
assigned to rate, total, grand total,
batch count, preset, set points,
units (lower display only),
alternating R & T, R & GT, preset
& rate, max & min, or a Modbus
display register. Any
rate/total/grand total display may
be programmed to alternate with a
custom unit or tag.
Alternating
Display
Displays alternate every 10
seconds when display is selected
or batch is paused.
Programming
Methods
Four programming buttons, digital
inputs, PC and MeterView Pro
software, or Modbus registers.
Noise Filter
Programmable from 2 to 199 (0 will
disable filter)
Filter Bypass
Programmable from 0.1 to 99.9%
of calibrated span
Recalibration
All ranges are calibrated at the
factory. Recalibration is
recommended at least every
12 months.
Max/Min
Display
Max/min readings reached by the
process are stored until reset by
the user or until power to the
controller is turned off.
Password
Three programmable passwords
restrict modification of
programmed settings.
Pass 1: Allows use of function
keys and digital inputs
Pass 2: Allows use of function
keys, digital inputs and editing
set/reset points
Pass 3: Restricts all programming,
function keys, and digital inputs
Total: Prevents resetting the total
manually
Gtotal: Prevents resetting the
grand total manually.
Power Options
85-265 VAC 50/60 Hz, 90-265
VDC, 20 W max
or
12-24 VDC
10%, 15 W max
Powered over USB for configuration
only.
Isolated
Transmitter
Power Supply
Terminals P+ & P-: 24 VDC
10%.
12-24 VDC powered models
selectable for 24, 10, or 5 VDC supply
(internal P+/P- switch).
85-265 VAC models rated @ 200 mA
max, 12-24 VDC powered models
rated @ 100 mA max, @ 50 mA max
for 5 or 10 VDC supply.
Non-Volatile
Memory
All programmed settings are stored
in non-volatile memory for a
minimum of ten years if power is
lost.