PDW30 Point-to-Point Wireless Bridge Instruction Manual
7
Pre-Installed Conduit Plug
The PDW30 is supplied with one pre-installed optional conduit plug for installations that do not require the
use of both conduit entries. The conduit plug includes an internal hexagonal socket recess for removal.
Mounting Instructions
The PDW30 has two
mounting holes that may be used for a 1.5” pipe mounting or wall mounting. Alterna-
tively, the unit may be supported by the conduit using the conduit holes provided. The antenna is
threaded into one of the three conduit holes and may be moved as appropriate for the installation.
It can also be mounted by using the PDA6963 mounting bracket in order to orient the device antenna
away from the pipe. Refer to Mounting Dimensions on page 28 for details on wall or panel space require-
ments.
Cover Jam Screw
The cover jam screw should be properly installed once the meter has been wired and tested in a safe en-
vironment. The cover jam screw is intended to prevent the removal of the meter cover in a flameproof en-
vironment without the use of tools. Using a M2 hex wrench, turn the screw clockwise until the screw con-
tacts the meter. Turn the screw an additional 1/4 to 1/2 turn to secure the cover.
Caution:
Excess torque may damage the threads and/or wrench.
FCC Notice
Contains FCC ID: MCQ-XB900HP
The enclosed device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (i.) this device may not cause harmful interference and (ii.) this device must accept any inter-
ference received, including interference that may cause undesired operation.
IMPORTANT
The RF module has been certified for remote and base radio applications. If the module will be used for
portable applications, the device must undergo SAR testing. This equipment has been tested and found
to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be deter-
mined by turning the equipment off and on, the user is encouraged to try to correct the interference by
one or more of the following measures: Re-orient or relocate the receiving antenna, Increase the separa-
tion between the equipment and receiver. Connect equipment and receiver to outlets on different circuits,
or consult the dealer or an experienced radio/TV technician for help.
Canada (IC) Notice
Contains Model: XB900HP, IC: 1846A-XB900HP
Integrator is responsible for its product to comply with IC ICES-003 & FCC Part 15, Sub. B - Unintentional
Radiators. ICES-003 is the same as FCC Part 15 Sub. B and Industry Canada accepts FCC test report or
CISPR 22 test report for compliance with ICES-003.