Technical Instructions
MT15000/2
MT15000/2-M
Страница 1: ...Technical Instructions MT15000 2 MT15000 2 M ...
Страница 2: ...e connection 4 MT15000 EXT4 and MT15000 EXT4 M extension modules connection 5 Connecting a fail safe electric strike and electro magnet 6 Connecting a standard strike 7 MT15000 2 control unit connection to Ethernet network 8 SWAMIGO3 dongle installation 9 Terminal block features 10 Reset buttons use 11 Dear Customer You have purchased a MT15000 2 control unit produced by PRASTEL France We thank yo...
Страница 3: ...ic shock or fire Please read these technical instructions before installing the product and follow assembly instructions thereof All internal capacitors in the 220V version will lose charge at a healthy level after 60 seconds once power has been turned off under normal conditions However in the event of a failure the charge may be main tained for much longer and adequate precautions are required b...
Страница 4: ...wires near other high voltage or current cables including 220V and higher Note Each reader may support a separate technology Example Reader 1 in Wiegand Reader 2 in Data Clock WIEGAND o proximity reader PRASTEL HID STID INDALA o keypad PRASTEL XPR o Biometric readers PRASTEL o Radio receivers PRASTEL o DALLAS via interface DATA CLOCK o Magnetic strip readers o Bar codes readers o Proximity reader ...
Страница 5: ...MODULES CONNECTION MT15000 2 MT15000 EXT4 A A B B You may also use A and B terminal blocks on MT15000 EXT4 modules to connect your RS485 bus Information 2 wires 2 pairs recommended Max Distance 750m Cable Type 0 6 mm SYT recommended Warning Do not connect the wires near other high voltage or current cables including 220V and higher Make sure to use the same pair for wires A and B A B Up to 10 modu...
Страница 6: ...main operational when not receiving power Warning The anti reverse diodes delivered with the control unit must be used and connected as shown in the above wiring diagram in order to avoid any unpredictable malfunctions caused by back currents that might disturb the system s appropriate performance The above wiring diagram must be followed even when using an additional backup power supply for locki...
Страница 7: ...nti reverse diodes delivered with the control unit must be used and connected as shown in the above wiring diagram in order to avoid any unpredictable malfunctions caused by back currents that might disturb the system s appropriate performance The above wiring diagram must be followed even when using an additional backup power supply for locking which is separate to the control unit power supply D...
Страница 8: ...s is indicated on sticker on the control unit casing To set a different IP address you can use the menu automatic detection of SWAMIGO3 For that purpose proceed as follows After creating the installation at the first launch SWAMIGO3 suggests to create a new control unit Click Search A list of all the detected control units appears Double click on the control unit you wish to add to the installatio...
Страница 9: ...ired Up to 10 readers SWAMIGO3 10 Dongle required Up to 40 readers SWAMIGO3 40 Dongle required Up to 140 readers SWAMIGO3 140 Dongle required Up to 840 readers SWAMIGO3 840 Dongle required Dongle installation While power supply is turned off install the dongle proceeding as follows To check if system is running regularly SWAMIGO3 indicates the version you are using at the bottom of the main window...
Страница 10: ...T15000 2 V1 0 ENGLISH p 10 11 PRASTEL France SARL ZI Athélia II 225 Impasse du Serpolet 13704 LA CIOTAT Cedex France Tel 33 442 98 06 06 Fax 33 442 04 53 51 infos prastelfrance fr TERMINAL BLOCK FEATURES ...
Страница 11: ...s IP address 192 168 2 150 mask 255 255 255 0 Cut off the power supply Keep the switch pushed while turning on the power supply Wait for the relays activation approximately 20 seconds while keeping the switch pushed Release the switch To erase the control unit memory Cut off the power supply Keep the switch pushed while turning on the power supply Wait for the relays activation approximately 20 se...